24Installing the DFC on systems equipped with a BIC

Installing the DFC in the NAM

1.

Ground yourself by attaching one end of the grounding strap to your wrist and

 

the other end to a grounded metal surface.

 

 

 

2.

If you have a NAM II, locate slot 8 on the expansion bus. If you have a new

 

NAM, locate slot 1 on the expansion bus. Remove the slot cover screw and

 

the metal slot cover from the slot. Keep the metal slot cover and screw. You

 

will have to re-install the metal slot cover if you remove the DFC.

3.

Switch SW1 should be set according to the following table:

 

 

 

 

 

 

 

 

 

 

Position

8

7

6

5

4

3

2

1

 

 

 

 

 

 

 

 

 

 

 

State

off

on

off

off

on

on

on

on

 

 

 

 

 

 

 

 

 

 

 

 

4.

Switch SW2 should be set according to the following table:

 

 

 

 

 

 

 

 

 

 

Position

2

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

State

on

on

 

 

 

 

 

 

 

 

 

 

 

 

5.

Ensure there is a jumper on position 10 of the INTERRUPT.

 

Note: The settings in these table are the default values and should be set

 

 

properly when the board is received. Refer to Figure 12 on page 17 for

 

 

the location of the switch SW1, SW2 and the INTERRUPT jumpers.

6.

Carefully hold the DFC along the top only. Insert the card by aligning

 

between the metal groove on one side and the slot opening on the other side.

7.

Push the DFC straight in until it is snugly in place. Ensure the edge connector

 

is firmly inserted into the socket.

 

 

 

 

 

8.

Fasten the slot cover screw in the DFC slot cover.

 

 

Connecting the DFC to the BIC with the PEB Cable

There are no fiber connections to the DFC. The DFC uses the voice ports on the BIC to connect the fax ports to fax machines or a call.

Only one DFC can be installed in a NAM. The DFC connects to the BEC daughterboard attached to the BIC through the PCM Expansion Bus (PEB) cable. This cable must be connected from the DFC to the BIC. The PEB cable connects the DFC to the BIC to share the ports connected to the Norstar KSU.

FAX Installation Guide

P0886634 Issue 1.0

Image 30
Contents Norstar Voice Mail 4.0 FAX Installation Guide Page Contents FAX Installation Guide Regulatory information Repair facilities Introduction to Norstar Voice Mail FAX FAX overviewFAX overview DFC overview SpecificationsSpecial tools Precautions Enabling the FAX softwareDVCs Installation overview Shutting down the Norstar Voice Mail systemOpening the NAM Unlocking the module doorInstalling the DFC in the NAM Locating the expansion bus slots on a NAM Switch SW1 should be set according to the following table Installing the PEB Cable NAM PEB Cable installation exampleDigital Voice Card Installing the PEB Cable Adding a Digital Voice Card after FAX is installed Installing the DFC on systems equipped with DVCs P0886634 Issue BIC Removing the BIC Keyboard/mouse backplane connector JP1 JP2 BIC connection points Re-installing the BIC in the NAM Re-installing the BIC in a NAMRe-installing the BIC in a new NAM Connecting the DFC to the BIC with the PEB Cable Connecting the BIC to the DFC in a NAM To connect the BIC to the DFC with the PEB cable Enabling the FAX software P0886634 Issue USA Comments Optional Your name Fax Company Norstar is a trademark of Northern Telecom. P0886634 Issue