24Installing the DFC on systems equipped with a BIC
Installing the DFC in the NAM
1. | Ground yourself by attaching one end of the grounding strap to your wrist and | |||||||||
| the other end to a grounded metal surface. |
|
|
| ||||||
2. | If you have a NAM II, locate slot 8 on the expansion bus. If you have a new | |||||||||
| NAM, locate slot 1 on the expansion bus. Remove the slot cover screw and | |||||||||
| the metal slot cover from the slot. Keep the metal slot cover and screw. You | |||||||||
| will have to | |||||||||
3. | Switch SW1 should be set according to the following table: | |||||||||
|
|
|
|
|
|
|
|
|
| |
Position | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 |
| |
|
|
|
|
|
|
|
|
|
| |
State | off | on | off | off | on | on | on | on |
| |
|
|
|
|
|
|
|
|
|
|
|
4. | Switch SW2 should be set according to the following table: | |||||||||
|
|
|
|
|
|
|
|
|
| |
Position | 2 | 1 |
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
| |
State | on | on |
|
|
|
|
|
|
| |
|
|
|
|
| ||||||
5. | Ensure there is a jumper on position 10 of the INTERRUPT. | |||||||||
| Note: The settings in these table are the default values and should be set | |||||||||
|
| properly when the board is received. Refer to Figure 12 on page 17 for | ||||||||
|
| the location of the switch SW1, SW2 and the INTERRUPT jumpers. | ||||||||
6. | Carefully hold the DFC along the top only. Insert the card by aligning | |||||||||
| between the metal groove on one side and the slot opening on the other side. | |||||||||
7. | Push the DFC straight in until it is snugly in place. Ensure the edge connector | |||||||||
| is firmly inserted into the socket. |
|
|
|
|
| ||||
8. | Fasten the slot cover screw in the DFC slot cover. |
|
|
Connecting the DFC to the BIC with the PEB Cable
There are no fiber connections to the DFC. The DFC uses the voice ports on the BIC to connect the fax ports to fax machines or a call.
Only one DFC can be installed in a NAM. The DFC connects to the BEC daughterboard attached to the BIC through the PCM Expansion Bus (PEB) cable. This cable must be connected from the DFC to the BIC. The PEB cable connects the DFC to the BIC to share the ports connected to the Norstar KSU.