SkyLink am-100 Control Panel, Programming Passwords, Changing Passwords, Questions Solutions

Page 11

TROUBLE SHOOTING

Control Panel

Questions

Solutions

Why I can’t arm my system?

Make sure none of the sensors are

 

triggered. You can check this by the zone

 

LEDs, none of them should blink.

 

 

I cannot arm the system even when no

You need to disarm the system again by

sensor is triggered, and the ARM LED

either entering the password or disarm by

is off.

keychain remote. Although the ARM LED

 

is off, but the system is not completely

 

disarmed after an alarm was triggered.

 

Refer to page 19 on how to completely

 

disarm a control panel after an alarm has

 

been triggered.

 

 

Why the ARM LED keeps flashing?

That means you have not programmed any

 

emergency phone numb ers. For instructions

 

on how to program emergency phone

 

numbers, please see page 10.

 

 

How do I exit programming mode

You can press the programming button on

when I’m in the middle of it?

the side of the unit to quit programming

 

anytime.

 

 

When a sensor is triggered, the alarm

You have programmed that sensor in alarm

sounds instantly even it is not armed,

mode, instead of beep mode. Please refer

why is that?

to page 26 for instructions of how to program

 

it back to beep mode.

 

 

When the alarm is triggered, why

The control panel will stop calling when it

the control panel won’t call all the

is disarmed by any one of the recipients.

programmed phone numbers? It

Disarm can also be done locally thru the

always stops before calling the

keypad on the control panel by entering a

last number.

valid password.

 

 

Why the control panel doesn’t beep

You have placed the buzzer mode selector

when a sensor is triggered, while

on the side of the control panel to “II”, this

only the zone LED flashes?

will disable the beeping. Placing it to “I” will

 

enable the beeping.

 

 

The control panel is in armed mode,

If the triggered sensor is programmed in the

why activating a sensor will not cause

Alert Zone (Bypass Zone), alarm will not

an alarm, or call any emergency phone

sound, and emergency call will not be made

number?

if this sensor is triggered. The control panel

 

will only respond when it is disarmed, in

 

alert mode.

 

 

44

INSTALLATION

Programming Passwords

Master Password can be used for programming, arming, disarming the system, and telephone access. The default Master Password is [1234].

Secondary Password can be used for arming, disarming the system, and telephone access. Secondary Password cannot be used for programming. The default Secondary Password is [0000].

Duress Password is used when you are forcibly compelled to disarm the control panel. Entering the duress password will stop the siren from sounding but the control panel will silently call the emergency phone numbers for help. The default Duress Password is [3838]. You should definitely change this password and let all the users know this password.

Changing Passwords

It is strongly recommended to change all 3 passwords when you first set up the system.

In order to change the password, follow the procedures below.

Step

Keys

Function

Description

Note

 

 

 

 

 

1

[PROG]

Enter

Enter master

3 beeps for valid

 

[MPIN]

Programming

password to

password. 1 long

 

mode

programming mode

beep for invalid

 

 

 

 

password.

 

 

 

 

 

2

[2]

Select

 

 

 

 

password

 

 

 

 

programming

 

 

 

 

 

 

 

3

[1] or

Select which

[1] - Master password

 

 

[2] or

password to

[2] - Secondary password

 

 

[3]

change

[3] - Duress password

 

 

 

 

 

 

4

[new

Enter new

Select any 4-digit pass-

 

 

4-digit

password

word, each digit can be

 

 

password]

 

from 0 to 9

 

 

 

 

 

 

5

[new

Enter new

Enter the new password

3 beeps if new pass-

 

4-digit

password to

again for confirmation

word is accepted. You

 

password]

confirm

 

will hear [Password

 

 

 

 

Accepted]

 

 

 

 

 

9

Image 11
Contents Skylink Group Email support@skylinkhome.comHome Smart Center EMC Declaration of ConformityPage FCC Information Consumer Information ContentIntroduction System ConfigurationAccessories Introduction Accessories Installing the Console InstallationEnglish Trouble ShootingSensors FrenchQuestions Solutions Programming PasswordsChanging Passwords Order to change the password, follow the procedures belowPhone Number Programming Home AutomationEvent Trigger Testing Phone NumbersThis is not a Control MODULE, THEREFORE, should not be Installing Door / Window SensorsTesting Mounting the SensorErase Control Modules Installing Motion SensorInsert Battery OperationPart 2 Learn signal from Control Panel to Control Module Operation Alert ModePart 1 Learn signal from Control Module to Control Panel Alert Mode ExamplesTo indicate the light has been turned on MuteLearn Control Modules Send back a confirmation to the control panelArming the System Advanced Programming OperationSystem Status Erase SensorsLearn Sensors Continue Entering the premises Enter password withinAdvanced Programming Disarming the systemDisarming under Duress Learn SensorsDisarming a triggered control panel Phone Line Failure PanicSystem Failure Erase Keychain / Keypad RemotesControl Panel Low BatteryLearn Keychain / Keypad Remotes Sensor FailureKeychain Remote To enable alert zone feature, follow the instructions belowReceiving the Emergency Call It is recommend to enable alert zone ifAdvanced Programming Communication Remote Operation by Telephone To access the control panel away from homeCalling in when you are away from home To enable auto mute feature, follow the instructions belowExample Remote Phone OperationsSystem Armed Alarm Mode Beep / AlarmSystem Disarmed Alert Mode
Related manuals
Manual 28 pages 6.36 Kb

am-100 specifications

The SkyLink AM-100 is an innovative satellite communication system designed to provide seamless connectivity in remote and challenging environments. This system caters to a diverse range of industries, including maritime, aviation, and disaster recovery, delivering reliable communication solutions even in the most isolated locations.

One of the standout features of the SkyLink AM-100 is its compact and lightweight design, making it easy to transport and deploy in various scenarios. Weighing less than 10 pounds, the unit allows users to establish a communication link in a matter of minutes. The system also boasts rugged construction, enabling it to withstand harsh environmental conditions and ensuring continuous operation in extreme temperatures, humidity, and dust.

The AM-100 leverages advanced satellite technologies that allow for high-speed data transmission. With a bandwidth capacity that supports voice, video, and data services, users can experience real-time communication capabilities that are critical for timely decision-making and action in emergencies or pivotal situations. The system can provide a data rate of up to 5 Mbps, ensuring that users can send and receive large files or stream video feeds without interruption.

Another key characteristic of the SkyLink AM-100 is its user-friendly interface. The system features an intuitive control panel and easily accessible connectivity ports, simplifying the setup process. Users can quickly adapt the system for various applications, whether for on-the-ground operations or aerial surveillance.

Additionally, the AM-100 is designed with multi-network support, enabling users to switch between different satellite networks for enhanced reliability. This flexibility is particularly beneficial in regions with varying network availability, ensuring continuous service and connectivity.

Security is also a major focus of the SkyLink AM-100 system. It incorporates advanced encryption protocols to protect sensitive data and communications, making it suitable for military and governmental operations.

In conclusion, the SkyLink AM-100 stands out with its robust features, including portability, high-speed data capabilities, ease of use, multi-network support, and strong security measures. It is an essential tool for professionals requiring reliable connectivity in remote locations, helping to bridge the communication gap in critical situations. Whether for disaster relief, on-site operations, or remote monitoring, the SkyLink AM-100 is poised to deliver exceptional performance and reliability.