INSTALLATION

HOME AUTOMATION

Installing Door / Window Sensors

Window / Door Sensor is used to monitor doors or windows that open and close. When these doors / windows are open or closed, the sensors will transmit a signal to the control panel to notify the user. These sensors consist of 2 parts, one is the transmitter, the other is the magnet.

Transmitter Magnet

 

ZONE LED

DESCRIPTION

 

Off

Zone is not occupied by any control module

 

 

 

 

Flashes twice

That means a remote has occupied that zone.

 

 

THIS IS NOT A CONTROL MODULE, THEREFORE, SHOULD NOT BE

 

 

ERASED.

 

 

 

 

Flashes once

That zone is occupied by a control module. You may select this

Before installing the sensor, remove the battery isolator by pulling out the yellow tab. Once the isolator is removed, the control panel will announce the sensor's status, such as "Zone 1 Sensor 1 Triggered", and corresponding zone LED will flash and buzzer will beep. If the magnetic contact is closed, the beeping will stop.

Note:

-Both Window/Door Sensors have been programmed at the factory. They are Zone 1 Sensor 1 and Zone 2 Sensor 1. Trigger the sensor and listen to the announcement to determine which one is zone 1 and which is zone 2.

Mounting the Sensor

The transmitters should be mounted on the door frame or window frame by double sided tape. The magnet should be mounted on the door or window by either double sided tape or screws. Make sure the magnet is aligned with the red marking on the transmitter. If the surface of the frame is flat enough, double- sided foam tape is sufficient, otherwise, it is recommended to screw the mounting plate to the frame, then apply double sided tape. After mounting the sensor, if the AAA+ logo is inverted, remove the front cover and rotate it so the AAA+ logo is in the upright position.

Magnet

Magnet

"Red Marking"

"Red Marking"

Sensor

Sensor

Magnet on the left

Magnet on the right

Mounting plate

Double-sided Sensor

 

 

and screws

foam tape

 

 

(optional)

 

Testing:

After mounting the sensor, test the sensor by opening and closing the door or window. Open the door or window will result in the followng:

1.Voice announcement - Announce the triggered zone and sensor

2.Beeping - The number of beep represents the zone number

3.Zone LED flashing - Number of flash represents the sensor number.

12

 

zone to erase this control module.

 

 

Flashes once,

That means this zone is occupied by a remote AND a control module.

then twice

You may select this zone to erase the control module.

**Table F: Zone LED status for erasing control module.

Part 2 Erase communication from Control Panel to Control Module

Step

Keys

Function

Description

Note

 

 

 

 

 

1

Remove the

Enter program-

Enter master

3 beeps for valid

 

control module

ming mode

password to

password. 1 long

 

from the

 

programming

beep for invalid

 

electrical outlet

 

mode

password.

 

 

 

 

 

2

Press and hold

To erase the

 

Control module LED

 

the learn button

memory of the

 

will flash rapidly

 

on the control

control module

 

indicating all the

 

module while

 

 

memory is erased.

 

plugging in the

 

 

You may now

 

control module

 

 

release the learn

 

to an electrical

 

 

button.

 

outlet.

 

 

 

 

 

 

 

 

Once the memory of the control module is erased, all of its memory is cleared. If you have other remotes / control panels controlling this control module, you need to re-program those remotes / control panels.

41

Image 14
Contents Email support@skylinkhome.com Skylink GroupHome Smart Center Declaration of Conformity EMCPage Content FCC Information Consumer InformationSystem Configuration IntroductionAccessories Introduction Accessories Installation Installing the ConsoleFrench Trouble ShootingSensors EnglishOrder to change the password, follow the procedures below Programming PasswordsChanging Passwords Questions SolutionsHome Automation Phone Number ProgrammingTesting Phone Numbers Event TriggerMounting the Sensor Installing Door / Window SensorsTesting This is not a Control MODULE, THEREFORE, should not beOperation Installing Motion SensorInsert Battery Erase Control ModulesPart 2 Learn signal from Control Panel to Control Module Alert Mode Examples Alert ModePart 1 Learn signal from Control Module to Control Panel OperationSend back a confirmation to the control panel MuteLearn Control Modules To indicate the light has been turned onErase Sensors Advanced Programming OperationSystem Status Arming the SystemDisarming the system Entering the premises Enter password withinAdvanced Programming Learn Sensors ContinueDisarming under Duress Learn SensorsDisarming a triggered control panel Erase Keychain / Keypad Remotes PanicSystem Failure Phone Line FailureSensor Failure Low BatteryLearn Keychain / Keypad Remotes Control PanelTo enable alert zone feature, follow the instructions below Keychain RemoteReceiving the Emergency Call It is recommend to enable alert zone ifAdvanced Programming Communication To enable auto mute feature, follow the instructions below To access the control panel away from homeCalling in when you are away from home Remote Operation by TelephoneRemote Phone Operations ExampleSystem Armed Alarm Mode Beep / AlarmSystem Disarmed Alert Mode
Related manuals
Manual 28 pages 6.36 Kb

am-100 specifications

The SkyLink AM-100 is an innovative satellite communication system designed to provide seamless connectivity in remote and challenging environments. This system caters to a diverse range of industries, including maritime, aviation, and disaster recovery, delivering reliable communication solutions even in the most isolated locations.

One of the standout features of the SkyLink AM-100 is its compact and lightweight design, making it easy to transport and deploy in various scenarios. Weighing less than 10 pounds, the unit allows users to establish a communication link in a matter of minutes. The system also boasts rugged construction, enabling it to withstand harsh environmental conditions and ensuring continuous operation in extreme temperatures, humidity, and dust.

The AM-100 leverages advanced satellite technologies that allow for high-speed data transmission. With a bandwidth capacity that supports voice, video, and data services, users can experience real-time communication capabilities that are critical for timely decision-making and action in emergencies or pivotal situations. The system can provide a data rate of up to 5 Mbps, ensuring that users can send and receive large files or stream video feeds without interruption.

Another key characteristic of the SkyLink AM-100 is its user-friendly interface. The system features an intuitive control panel and easily accessible connectivity ports, simplifying the setup process. Users can quickly adapt the system for various applications, whether for on-the-ground operations or aerial surveillance.

Additionally, the AM-100 is designed with multi-network support, enabling users to switch between different satellite networks for enhanced reliability. This flexibility is particularly beneficial in regions with varying network availability, ensuring continuous service and connectivity.

Security is also a major focus of the SkyLink AM-100 system. It incorporates advanced encryption protocols to protect sensitive data and communications, making it suitable for military and governmental operations.

In conclusion, the SkyLink AM-100 stands out with its robust features, including portability, high-speed data capabilities, ease of use, multi-network support, and strong security measures. It is an essential tool for professionals requiring reliable connectivity in remote locations, helping to bridge the communication gap in critical situations. Whether for disaster relief, on-site operations, or remote monitoring, the SkyLink AM-100 is poised to deliver exceptional performance and reliability.