SkyLink am-100 manual Panic, System Failure, Erase Keychain / Keypad Remotes, Phone Line Failure

Page 22

OPERATION

Panic

Pressing the panic button on the control

OR

panel or keychain remote will cause the

 

siren to sound and outgoing calls will

 

be made to the preprogrammed phone

 

numbers, “System Panic” will also be

 

announced. This can be used in any

 

emergency situation.

 

To stop the siren and disarm the system, user can enter a valid password, or press the disarm button on the keychain remote. This will terminate the siren and the control panel from calling the rest of the emergency phone numbers.

ARM

PANIC

DISARM

AUX

- Control other Skylink receiver such as Garage Door Receiver - Model 18R

System Failure

Control Panel constantly monitors itself and its sensors. If there are any trouble conditions, the control panel will advise the user. These trouble conditions include:

-Phone Line Failure

-Sensor Failure (loss of supervisory signal)

-Low Battery – Control Panel

-Low Battery – Sensors

Phone Line Failure

When the phone line is disconnected or malfunctions, the control panel will instantly notify the user by:

1.Both Power [PWR] and Program [PROG] LEDs will flash together;

2.Voice announcement “Phone Line Failure” will be played.

When phone line failure occurs, please check the phone line connection, ensure the phone line is plugged into both the control panel and the wall socket securely. You should also check the phone line with a normal telephone to determine if it can dial out to a phone number. If it cannot dial out, that indicates the phone line is not in service, you should contact your local phone company.

20

 

ADVANCED PROGRAMMING

 

Remote [6] is represented by zone LED 1

 

®

ZONE LED

REMOTE LOCATION

1

6

2

7

3

8

4

9

5

0

Erase Keychain / Keypad Remotes

Follow the instructions below to erase keychain or keypad remotes / receivers.

Step

 

Keys

 

Function

Description

Note

 

 

 

 

 

 

 

1

 

[PROG]

Enter

Enter master

3 beeps for valid

 

 

[MPIN]

 

Programming

password to pro-

password. 1 long beep

 

 

 

 

 

mode

gramming mode

for invalid password.

2

 

[0]

 

 

Select erase

 

After [0] is entered, some

 

 

 

 

 

remote

 

zone LEDs will flash or stay

 

 

 

 

 

programming

 

off. The zone LEDs

 

 

 

 

 

 

 

represent whether that zone

 

 

 

 

 

 

 

is occupied by any remote.

 

 

 

 

 

 

 

** See Table B below.

3

 

To erase

Select remote

Select a remote

After you have selected the

 

an occupied

location you

location [6], [7],

remote location, you will hear 3

 

 

remote, press

would like to

[8], [9] or [0].

beeps and verbal confirmation

 

 

[6] to [0].

erase

 

[Device X Empty Memory],

 

 

 

 

 

 

 

where X is the remote location

 

 

 

 

 

 

 

you have selected.

 

 

 

 

 

 

ZONE LED

 

 

DESCRIPTION

 

 

 

 

 

 

 

Off

 

 

Zone is not occupied by any remote

 

 

 

 

Flashes twice

 

This zone is occupied by a remote. You may select this zone to

 

 

 

 

erase this remote.

 

 

 

 

 

Flashes once

 

This zone is occupied by a control module (Optional).

 

 

 

 

THIS IS NOT A REMOTE CONTROL, THEREFORE, SHOULD NOT BE

 

 

 

 

ERASED. (Refer to page 40 Erase Control Module for more

 

 

 

 

information)

 

 

 

 

 

Flashes once,

 

This zone is occupied by a remote AND a control module.

then twice

 

 

You may select this zone to erase the remote.

 

 

 

 

 

 

 

 

** Table B: Zone LED status for erasing keychain/keypad remote(s).

* Please refer to erase control module on page 40.

33

Image 22
Contents Email support@skylinkhome.com Skylink GroupHome Smart Center Declaration of Conformity EMCPage Content FCC Information Consumer InformationSystem Configuration IntroductionAccessories Introduction Accessories Installation Installing the ConsoleFrench Trouble ShootingSensors EnglishOrder to change the password, follow the procedures below Programming PasswordsChanging Passwords Questions SolutionsHome Automation Phone Number ProgrammingTesting Phone Numbers Event TriggerMounting the Sensor Installing Door / Window SensorsTesting This is not a Control MODULE, THEREFORE, should not beOperation Installing Motion SensorInsert Battery Erase Control ModulesPart 2 Learn signal from Control Panel to Control Module Alert Mode Examples Alert ModePart 1 Learn signal from Control Module to Control Panel OperationSend back a confirmation to the control panel MuteLearn Control Modules To indicate the light has been turned onErase Sensors Advanced Programming OperationSystem Status Arming the SystemDisarming the system Entering the premises Enter password withinAdvanced Programming Learn Sensors ContinueDisarming a triggered control panel Learn SensorsDisarming under Duress Erase Keychain / Keypad Remotes PanicSystem Failure Phone Line FailureSensor Failure Low BatteryLearn Keychain / Keypad Remotes Control PanelTo enable alert zone feature, follow the instructions below Keychain RemoteAdvanced Programming Communication It is recommend to enable alert zone ifReceiving the Emergency Call To enable auto mute feature, follow the instructions below To access the control panel away from homeCalling in when you are away from home Remote Operation by TelephoneRemote Phone Operations ExampleSystem Disarmed Alert Mode Beep / AlarmSystem Armed Alarm Mode
Related manuals
Manual 28 pages 6.36 Kb

am-100 specifications

The SkyLink AM-100 is an innovative satellite communication system designed to provide seamless connectivity in remote and challenging environments. This system caters to a diverse range of industries, including maritime, aviation, and disaster recovery, delivering reliable communication solutions even in the most isolated locations.

One of the standout features of the SkyLink AM-100 is its compact and lightweight design, making it easy to transport and deploy in various scenarios. Weighing less than 10 pounds, the unit allows users to establish a communication link in a matter of minutes. The system also boasts rugged construction, enabling it to withstand harsh environmental conditions and ensuring continuous operation in extreme temperatures, humidity, and dust.

The AM-100 leverages advanced satellite technologies that allow for high-speed data transmission. With a bandwidth capacity that supports voice, video, and data services, users can experience real-time communication capabilities that are critical for timely decision-making and action in emergencies or pivotal situations. The system can provide a data rate of up to 5 Mbps, ensuring that users can send and receive large files or stream video feeds without interruption.

Another key characteristic of the SkyLink AM-100 is its user-friendly interface. The system features an intuitive control panel and easily accessible connectivity ports, simplifying the setup process. Users can quickly adapt the system for various applications, whether for on-the-ground operations or aerial surveillance.

Additionally, the AM-100 is designed with multi-network support, enabling users to switch between different satellite networks for enhanced reliability. This flexibility is particularly beneficial in regions with varying network availability, ensuring continuous service and connectivity.

Security is also a major focus of the SkyLink AM-100 system. It incorporates advanced encryption protocols to protect sensitive data and communications, making it suitable for military and governmental operations.

In conclusion, the SkyLink AM-100 stands out with its robust features, including portability, high-speed data capabilities, ease of use, multi-network support, and strong security measures. It is an essential tool for professionals requiring reliable connectivity in remote locations, helping to bridge the communication gap in critical situations. Whether for disaster relief, on-site operations, or remote monitoring, the SkyLink AM-100 is poised to deliver exceptional performance and reliability.