SkyLink am-100 manual Learn Keychain / Keypad Remotes, Sensor Failure, Low Battery, Control Panel

Page 23

ADVANCED PROGRAMMING

Learn Keychain / Keypad Remotes

Additional keychain or keypad remotes can be programmed to the control panel. Maximum of 5 keychain/keypad remotes can be programmed to the control panel.

-Keychain or keypad remotes should be programmed to Device 6 to Device 0.

Follow the instructions below to program remote(s) to remote location(s) 6, 7, 8, 9, or 0, which is the bottom row of the numeric keypad of the control panel.

Step

 

Keys

 

Function

Description

 

Note

 

 

 

 

 

 

 

1

 

[PROG]

Enter Program-

Enter master

 

3 beeps for valid

 

 

[MPIN]

 

ming mode

password to

 

password. 1 long beep

 

 

 

 

 

 

programming mode

 

for invalid password.

2

 

[4]

 

 

Select learn

 

 

After [4] is entered, some

 

 

 

 

 

remote

 

 

zone LEDs will flash or

 

 

 

 

 

programming

 

 

stay off. The zone LEDs

 

 

 

 

 

 

 

 

represent whether that

 

 

 

 

 

 

 

 

zone is already occupied

 

 

 

 

 

 

 

 

by another remote.

 

 

 

 

 

 

 

 

** See Table A below.

 

 

 

 

 

 

 

3

 

[6] to [0]

Select remote

Select a remote

 

After you have selected

 

 

 

 

 

location

location [6], [7],

 

the remote location, that

 

 

 

 

 

(Max. 5 remotes)

[8], [9] or [0].

 

zone LED will be on.

 

 

 

 

 

 

 

4

 

Activate the

Trigger remote

Once the signal is

 

You will hear

 

 

remote by

 

transmitted to the

 

[Device X Accepted],

 

 

pressing any

 

Control Panel, that

 

where “X” is the remote

 

 

one of the

 

signal which will

 

location.

 

 

buttons.

 

be stored.

 

 

 

 

 

 

 

 

 

 

 

ZONE LED

 

 

DESCRIPTION

 

 

 

 

 

 

 

 

 

 

 

 

Off

 

 

Zone is not occupied by any remote

 

 

 

 

 

 

 

 

Flashes twice

 

This zone is occupied by another remote. Programming another

 

 

 

 

remote to this zone will overwrite the previous remote.

 

 

 

 

 

 

 

Flashes once

 

This zone is occupied by a control module* (Optional).

 

 

 

 

You can still program a remote to this zone, and it will not overwrite

 

 

 

 

the control module* you have in this zone. (Refer to page 37 Home

 

 

 

 

Automation for more information)

 

 

 

 

 

 

 

 

Flashes once,

 

This zone is occupied by a remote AND a control module*.

then twice

 

 

If you program another remote to this zone, it will overwrite the

 

 

 

 

previous remote, but not the control module*.

 

 

 

 

 

 

 

 

 

 

**Table A: Zone LED status for learning keychain/keypad remote(s).

*Please refer to learn control module on page 37.

32

OPERATION

Sensor Failure

The control panel constantly monitors its sensors, if the control panel fails to communicate with any sensors, it will notify the user by:

1.The zone LED of the failed sensor will be on steadily;

2.Voice announcement “zone X sensor Y failure” will be played.

When sensor failure occurs, try the following:

1.Check if the sensor is located at where it should be, and whether there is any physical damage to the sensor.

2.If the failed sensor is not physically damaged, try to activate the sensor and see if the control panel reacts to such activation.

3.If not, try to remove the sensor from its location, and bring it closer to control panel and activate the sensor. It is possible that the sensor is installed too far from the control panel and it cannot establish a steady communication with the control panel. If this is the case, please install the sensor closer to the control panel.

Low Battery

Control Panel

The control panel is powered mainly by the adapter. However, during power outage, it will be powered by the 4 AAA backup batteries. Under standby conditions, these batteries can last for 48 hours.

When the backup batteries are running low, the “LO BATT” LED on the control panel will be on, indicating you should replace the backup batteries. Ensure all 4 batteries are replaced altogether at the same time. After replacing the batteries, the “LO BATT” LED should be off, indicating the backup batteries are in good operating condition.

Sensors

All of the sensors are battery powered. Depending on the operating condition and environment, the battery life varies from 9 months to 2 years. 9V alkaline battery is used for the motion sensor, the battery life is approximately 9 months. Door / Window Sensor operates on a Lithium CR-2032 battery, with battery life of approxi- mately 2 years.

21

Image 23
Contents Skylink Group Email support@skylinkhome.comHome Smart Center EMC Declaration of ConformityPage FCC Information Consumer Information ContentIntroduction System ConfigurationAccessories Introduction Accessories Installing the Console InstallationEnglish Trouble ShootingSensors FrenchQuestions Solutions Programming PasswordsChanging Passwords Order to change the password, follow the procedures belowPhone Number Programming Home AutomationEvent Trigger Testing Phone NumbersThis is not a Control MODULE, THEREFORE, should not be Installing Door / Window SensorsTesting Mounting the SensorErase Control Modules Installing Motion SensorInsert Battery OperationPart 2 Learn signal from Control Panel to Control Module Operation Alert ModePart 1 Learn signal from Control Module to Control Panel Alert Mode ExamplesTo indicate the light has been turned on MuteLearn Control Modules Send back a confirmation to the control panelArming the System Advanced Programming OperationSystem Status Erase SensorsLearn Sensors Continue Entering the premises Enter password withinAdvanced Programming Disarming the systemDisarming under Duress Learn SensorsDisarming a triggered control panel Phone Line Failure PanicSystem Failure Erase Keychain / Keypad RemotesControl Panel Low BatteryLearn Keychain / Keypad Remotes Sensor FailureKeychain Remote To enable alert zone feature, follow the instructions belowReceiving the Emergency Call It is recommend to enable alert zone ifAdvanced Programming Communication Remote Operation by Telephone To access the control panel away from homeCalling in when you are away from home To enable auto mute feature, follow the instructions belowExample Remote Phone OperationsSystem Armed Alarm Mode Beep / AlarmSystem Disarmed Alert Mode
Related manuals
Manual 28 pages 6.36 Kb

am-100 specifications

The SkyLink AM-100 is an innovative satellite communication system designed to provide seamless connectivity in remote and challenging environments. This system caters to a diverse range of industries, including maritime, aviation, and disaster recovery, delivering reliable communication solutions even in the most isolated locations.

One of the standout features of the SkyLink AM-100 is its compact and lightweight design, making it easy to transport and deploy in various scenarios. Weighing less than 10 pounds, the unit allows users to establish a communication link in a matter of minutes. The system also boasts rugged construction, enabling it to withstand harsh environmental conditions and ensuring continuous operation in extreme temperatures, humidity, and dust.

The AM-100 leverages advanced satellite technologies that allow for high-speed data transmission. With a bandwidth capacity that supports voice, video, and data services, users can experience real-time communication capabilities that are critical for timely decision-making and action in emergencies or pivotal situations. The system can provide a data rate of up to 5 Mbps, ensuring that users can send and receive large files or stream video feeds without interruption.

Another key characteristic of the SkyLink AM-100 is its user-friendly interface. The system features an intuitive control panel and easily accessible connectivity ports, simplifying the setup process. Users can quickly adapt the system for various applications, whether for on-the-ground operations or aerial surveillance.

Additionally, the AM-100 is designed with multi-network support, enabling users to switch between different satellite networks for enhanced reliability. This flexibility is particularly beneficial in regions with varying network availability, ensuring continuous service and connectivity.

Security is also a major focus of the SkyLink AM-100 system. It incorporates advanced encryption protocols to protect sensitive data and communications, making it suitable for military and governmental operations.

In conclusion, the SkyLink AM-100 stands out with its robust features, including portability, high-speed data capabilities, ease of use, multi-network support, and strong security measures. It is an essential tool for professionals requiring reliable connectivity in remote locations, helping to bridge the communication gap in critical situations. Whether for disaster relief, on-site operations, or remote monitoring, the SkyLink AM-100 is poised to deliver exceptional performance and reliability.