SkyLink am-100 manual Learn Sensors, Disarming a triggered control panel, Disarming under Duress

Page 21

ADVANCED PROGRAMMING

Learn Sensors

You can program up to 10 sensors to the control panel. There are 5 zones on the control panel, each zone can program up to 2 sensors. Before program- ming a sensor, you must decide which sensor location (zone number and sensor number) you would like to program the sensor to. It is strongly recom- mended that you refer to “Sensor Location Selection Guide” before deciding which sensor location you would like to program the new sensors to. Some features you may need to consider are: 1) Beep/Alarm setting, 2) auto mute, 3) alert zone , 4) event trigger. Explanation for each feature can be found in the following pages in Advanced Programming:

1.Beep/Alarm Setting - Page 26

2.Auto Mute - Page 29

3.Alert Zone - Page 30

4.Event Trigger - Page 42

Sensor Location Selection Guide

You can program up to 10 sensors to the control panel. There are 5 zones and maximum 2 sesnors per zone. The 4 features mentioned above are Zone dependent features meaning both sensors in that zone will operate based on the setting for that zone. So if you program 2 sensors into one zone, those 2 sensors will react in the same manner for those zone dependent features. For example, if you enable the Auto-Mute feature for zone 1, both zone 1 sensor 1, and zone 1 sensor 2 will have this feature enabled. It is not possible to enable a zone dependent feature for sensor 1 only, but not sensor 2.

Therefore, the followings are some suggestions of how you should select the sensor location.

1.Check all the zone dependent features, and determine if you would like to enable any one of them.

2.If you decide not to enable any zone dependent features and keep the factory default setting, you can simply program the sensor to any sensor location based on your own preference. Omit the following steps and proceed to "Learn Sensor - Continue".

3.If you decide to enable some of the zone dependent features, check Table C below. Circle the zone dependent feature selections. If there are features that you would like to enable for more than 2 sensors, you need to select more than one zone for those features.

34

OPERATION

2.You must enter a valid password, either the Master Password, or Secondary Password to disarm the system before entry delay expires. The system can also be disarmed by pressing button 3 on the keychain remote.

3.When a valid password is entered, you will hear “System Disarmed” and the entry delay beeping will stop, the ARM LED will be off.

Note:

-The control panel can also be disarmed remotely when nobody is home, with a touch tone phone. Please refer to “Remote Operation by Telephone” on page 24.

-If 3 consecutive incorrect passwords are entered, alarm will sound immediately, the control panel will be in panic mode, and start calling the emergency phone numbers.

Disarming a triggered control panel

If "System Panic" is announced from the control panel after it has been disarmed, that means the alarm was triggered when it was in armed mode. Follow the procedures below to set the control panel back to standby mode.

1.If the alarm was caused by sensor(s), there will be flashing LEDs and beeping indicating which sensor(s) triggered the alarm. You may want to check the condition of the triggered sensor(s), the sensor(s) may be damaged if there were break-ins.

2.You need to reset the sensor manually by triggering it twice, i.e. open and then close a door / window sensor, or walk in front of the motion sensor. The LED representing that sensor will stop flashing after it receives the signal from the sensor.

3.You must now enter the password again on the control panel or press the disarm button on the keychain remote, as an acknowledgement of the alarm event. This will set the control panel back to standby mode.

Disarming under Duress

If you are forcibly compelled to disarm the control panel, you may enter the Duress Password. Entering the duress password will terminate the entry delay, i.e. no more entry delay beeping. But the control panel will silently call the emergency phone numbers for help. The called party will hear the voice announcement “System Panic”.

Note:

- The default duress password is [3838].

19

Image 21
Contents Skylink Group Email support@skylinkhome.comHome Smart Center EMC Declaration of ConformityPage FCC Information Consumer Information ContentIntroduction System ConfigurationAccessories Introduction Accessories Installing the Console InstallationSensors Trouble ShootingFrench EnglishChanging Passwords Programming PasswordsOrder to change the password, follow the procedures below Questions SolutionsPhone Number Programming Home AutomationEvent Trigger Testing Phone NumbersTesting Installing Door / Window SensorsMounting the Sensor This is not a Control MODULE, THEREFORE, should not beInsert Battery Installing Motion SensorOperation Erase Control ModulesPart 2 Learn signal from Control Panel to Control Module Part 1 Learn signal from Control Module to Control Panel Alert ModeAlert Mode Examples OperationLearn Control Modules MuteSend back a confirmation to the control panel To indicate the light has been turned onSystem Status Advanced Programming OperationErase Sensors Arming the SystemAdvanced Programming Entering the premises Enter password withinDisarming the system Learn Sensors ContinueLearn Sensors Disarming a triggered control panelDisarming under Duress System Failure PanicErase Keychain / Keypad Remotes Phone Line FailureLearn Keychain / Keypad Remotes Low BatterySensor Failure Control PanelKeychain Remote To enable alert zone feature, follow the instructions belowIt is recommend to enable alert zone if Advanced Programming CommunicationReceiving the Emergency Call Calling in when you are away from home To access the control panel away from homeTo enable auto mute feature, follow the instructions below Remote Operation by TelephoneExample Remote Phone OperationsBeep / Alarm System Disarmed Alert ModeSystem Armed Alarm Mode
Related manuals
Manual 28 pages 6.36 Kb

am-100 specifications

The SkyLink AM-100 is an innovative satellite communication system designed to provide seamless connectivity in remote and challenging environments. This system caters to a diverse range of industries, including maritime, aviation, and disaster recovery, delivering reliable communication solutions even in the most isolated locations.

One of the standout features of the SkyLink AM-100 is its compact and lightweight design, making it easy to transport and deploy in various scenarios. Weighing less than 10 pounds, the unit allows users to establish a communication link in a matter of minutes. The system also boasts rugged construction, enabling it to withstand harsh environmental conditions and ensuring continuous operation in extreme temperatures, humidity, and dust.

The AM-100 leverages advanced satellite technologies that allow for high-speed data transmission. With a bandwidth capacity that supports voice, video, and data services, users can experience real-time communication capabilities that are critical for timely decision-making and action in emergencies or pivotal situations. The system can provide a data rate of up to 5 Mbps, ensuring that users can send and receive large files or stream video feeds without interruption.

Another key characteristic of the SkyLink AM-100 is its user-friendly interface. The system features an intuitive control panel and easily accessible connectivity ports, simplifying the setup process. Users can quickly adapt the system for various applications, whether for on-the-ground operations or aerial surveillance.

Additionally, the AM-100 is designed with multi-network support, enabling users to switch between different satellite networks for enhanced reliability. This flexibility is particularly beneficial in regions with varying network availability, ensuring continuous service and connectivity.

Security is also a major focus of the SkyLink AM-100 system. It incorporates advanced encryption protocols to protect sensitive data and communications, making it suitable for military and governmental operations.

In conclusion, the SkyLink AM-100 stands out with its robust features, including portability, high-speed data capabilities, ease of use, multi-network support, and strong security measures. It is an essential tool for professionals requiring reliable connectivity in remote locations, helping to bridge the communication gap in critical situations. Whether for disaster relief, on-site operations, or remote monitoring, the SkyLink AM-100 is poised to deliver exceptional performance and reliability.