Frequency Range

1.6 to 27.5 MHz

Input Impedance

50 ohms (viewed from transceiver)

Antenna Required

7 to 30 meters wire or whip

Tuning Power

10 to 20 W pep

VSWR

Less than 1.5

Tuning Time

Within 2 to 15 seconds, Within 0.5 seconds for an ever tuned frequency

Dummy Load

10 ohms + 250 pF for check of Two-tone alarm generator at 2191 kHz

Power Requirement

15 VDC, 1A (supplied from transceiver)

Construction

Waterproof plastic cabinet, stainless steel mount

RECEIVER

Receiving System

Double-conversion superheterodyne

 

 

 

IF: 54.455 MHz and 455 kHz.

 

 

Sensitivity

Input level to produce SINAD 20 dB, or BER 10-2

 

 

 

J3E

J2B

 

 

1.6 - 4 MHz

Below +16 dBμV

Below +6 dBμV

across 10 Ω + 250 pF

 

4-27.5 MHz

Below +3 dBμV

Below -7 dBμV

across 50 Ω

Pass Band

350 - 2700 Hz

-6 dB

 

 

Cross Modulation

Unwanted signal +90 dBμV ±20 kHz from +60 dBμV wanted signal

Audio Output

2 W (8 Ω internal loudspeaker), 5 W (4Ω optional external loudspeaker)

 

0 dBm/600Ω line output (for NBDP, DSC)

 

Other Features

RF Gain:

Adjustable

 

 

 

Squelch:

ON/OFF, Activated by voice/signal strength

 

Dimmer:

OFF/Low/Medium/High

 

 

Loudspeaker:

ON/OFF (Handset always alive)

 

 

AGC:

ON/OFF

 

 

 

Noise blanker:

always ON

 

 

POWER AMP UNIT (Type PA-2500 for FS-1562-25)

Power capability

Input Power: 60 Wpep, Output Power: 250 Wpep

Input/Output Impedance

50 ohms

Power Supply

24 VDC, 30 A

DIMENSIONS

Transceiver Unit

108 mm(W) x 258 mm(H) x 300 mm(D), 6.5 kg

Antenna Coupler Unit

297 mm(W) x 390 mm(H) x 90 mm(D), 3.1 kg approx.

COMPASS SAFE DISTANCE

 

 

 

 

 

 

 

Unit

Standard

Steering

NOTE

 

 

Transceiver

1.2 m

0.9 m

 

 

 

Antenna coupler AT-1560-15

1.0 m

0.7 m

Furuno recommendation based on the

 

 

Antenna coupler AT-1560-25

1.0 m

0.7 m

ISO R 694 Method A tests for the

 

 

Handset

0.6 m

0.4 m

variant models, added with correction

 

 

PA-2500

0.9 m

0.7 m

factors which Furuno considers

 

 

PR-300

0.9 m

0.7 m

adequate.

 

 

 

 

 

PR-850A

1.0 m

0.7 m

 

 

 

 

 

 

 

 

vi

Image 8
Contents Page T 9 9 Safety Instructions Do not disassemble or modify the equipment List of Contents Features IntroductionSpecifications of MF/HF Radiotelephone model FS-1562 GeneralReceiver Operation Keys Front View of Transceiver UnitRotary controls Page Fuses Power Supply UnitAC and DC power switches Starting operation Selecting FrequencyTX Freq Standard type Netherlands type Special type YESDirect frequency entry J3ECustom channels ITU telephony channels SSBITU Telex channels Tuning the antenna Using the handsetMonitoring transceiver output power TransmittingReducing transmitter power Distress Call on 2182 kHzDistress frequencies Distress calls and Distress messageEvent of Antenna Coupler Failure DSC Distress CallingReceiving Frequency Scan Squelch controlNoise blanker NB Channel scanFrequency Sweep ITU channelsOptional Devices Telex CommunicationIntercom Remote StationSetting Page Page This page is intentionally left blank Weekly Checks Diagnostic TestTesting the transmitter with a dummy antenna Page LCD/Keyboard Test & ROM Version No. Confirmation Antenna Coupler Test Competent technicians onlyMaintenance Page Troubleshooting Troubleshooting List For qualified personnel onlyTrouble Probable Cause Remedy Error Indication Replacing FusesThis page is intentionally left blank Appendix MF band working carrier frequencies ref. US CFR 47 Part MF band SSB working carrier frequencies CH noMHz ITU SSB carrier frequencies ITU RR Appendix Following frequencies are factory programmedAP.5 12/16 MHz ITU SSB carrier frequencies ITU RR Appendix AP.7 Telex Channels MF Band Telex Frequency TableMHz Band ITU Nbdp Telex Frequency Table ITU RR AppendixAP.10 AP.11 12/16 MHz Band ITU Nbdp Telex Frequency Table AP.13 18/19 MHz Band ITU Nbdp Telex Frequency Table AP.15 22, 25/26 MHz Band ITU Nbdp Telex Frequency Table