Furuno FS-1562-25, FS-1562-15 manual Troubleshooting List For qualified personnel only

Page 37

Chapter 5 TROUBLESHOOTING

5.1 Troubleshooting List

For qualified personnel only

The troubleshooting list below gives common symptoms of equipment malfunction and means to restore normal operation. If you cannot restore normal operation, please do not check inside any unit. Any repair is best left to a qualified radiotelephone technician. Improper handling or adjustment may cause more serious damage.

Troubleshooting list

TROUBLE

PROBABLE CAUSE

REMEDY

 

 

 

Power can not be turned on

The mains switchboard may be

Turn on the mains switch.

 

off.

 

 

DC overvoltage input.

Check supply voltage. It should

 

The battery may have

be less than 31.2V

 

Recharge battery and tighten

 

discharged, or poor contact at

terminal connections.

 

terminals.

 

 

Check fuse on the power cable

Replace the blown fuses.

 

or Power Supply Unit.

 

 

 

 

Frequency readout appears

The [DIMMER] key may be

Operate the [DIMMER] key.

but no lamps light

off.

 

 

 

 

Power is on but no sound

The [SPEAKER] key is off.

Press the [SPEAKER] key.

from loudspeaker

Volume may be too low.

Adjust the VOLUME control.

 

 

Squelch is on.

Press the [SQ] key if "SQ"

 

 

appears on the display.

 

Reduced RF Gain.

Turn the RF Gain control

 

 

clockwise.

 

 

 

Poor articulation

Wrong class of emission may

Select class of emission same as

 

be in use. (For example,

that of incoming signal.

 

receiving signal in J3E mode.

 

 

J3E should be used only on

 

 

2182 kHz.)

In Custom or ITU channel

 

 

 

Receiver detuned.

mode, press the [CLARIFY]

 

 

key then fine tune frequency by

 

 

the FREQ/CH control.

 

 

 

Output power is reduced to

Power is automatically reduced

Wait until the unit returns to

low ("LOW" indication

to protect against overheating

normal condition.

blinks)

due to continuous transmission.

 

 

 

 

-5.1-

Image 37
Contents Page T 9 9 Safety Instructions Do not disassemble or modify the equipment List of Contents Introduction FeaturesGeneral Specifications of MF/HF Radiotelephone model FS-1562Receiver Operation Rotary controls Front View of Transceiver UnitKeys Page AC and DC power switches Power Supply UnitFuses Selecting Frequency Starting operationYES TX Freq Standard type Netherlands type Special typeJ3E Direct frequency entryITU telephony channels SSB Custom channelsITU Telex channels Using the handset Tuning the antennaMonitoring transceiver output power TransmittingDistress Call on 2182 kHz Reducing transmitter powerDistress calls and Distress message Distress frequenciesDSC Distress Calling Event of Antenna Coupler FailureReceiving Squelch control Frequency ScanNoise blanker NB Channel scanITU channels Frequency SweepTelex Communication Optional DevicesRemote Station IntercomSetting Page Page This page is intentionally left blank Testing the transmitter with a dummy antenna Diagnostic TestWeekly Checks Page LCD/Keyboard Test & ROM Version No. Confirmation Competent technicians only Antenna Coupler TestMaintenance Page Troubleshooting List For qualified personnel only TroubleshootingTrouble Probable Cause Remedy Replacing Fuses Error IndicationThis page is intentionally left blank Appendix MF band working carrier frequencies ref. US CFR 47 Part CH no MF band SSB working carrier frequenciesFollowing frequencies are factory programmed MHz ITU SSB carrier frequencies ITU RR AppendixAP.5 12/16 MHz ITU SSB carrier frequencies ITU RR Appendix AP.7 MF Band Telex Frequency Table Telex ChannelsITU RR Appendix MHz Band ITU Nbdp Telex Frequency TableAP.10 AP.11 12/16 MHz Band ITU Nbdp Telex Frequency Table AP.13 18/19 MHz Band ITU Nbdp Telex Frequency Table AP.15 22, 25/26 MHz Band ITU Nbdp Telex Frequency Table