Furuno FS-1562-25, FS-1562-15 manual LCD/Keyboard Test & ROM Version No. Confirmation

Page 33

4.3 LCD/Keyboard Test & ROM Version No. Confirmation

1.While pressing and holding down the [ENT] key, turn on the power. All LCD segments appear.

2.Release the [ENT] key.

3.Press keys one by one. Check if the indication on the operation display is correct as shown below:

Key

1

2

3

TX

Indication

Key

4

5

6

RX

Indication

Key

7

8

9

RCL

Indication

Key

2182

0

ALARM

ENT

Indication

Example: The [2] key is pressed. The following appears. In a few seconds, 7 characters x 2 lines readout change to all .

PRIVUSA

WXITU

ROM VERSION NO.

DUP CLAR

SIMP ABTR

0 2 4 6 8 10 SRF

0 1 2 3 4 5 ANTLOW TUNE OK SQ

ATTPREAGCNBSWEEPSCAN

MEMOREMCOMDUMMYTONE

LSBJ3ER3ECWH3ETLXFAX

Turn off the transceiver on completion of tests. Turn on again for normal operation.

-4.3-

Image 33
Contents Page T 9 9 Safety Instructions Do not disassemble or modify the equipment List of Contents Introduction FeaturesGeneral Specifications of MF/HF Radiotelephone model FS-1562Receiver Operation Front View of Transceiver Unit Rotary controlsKeys Page Power Supply Unit AC and DC power switchesFuses Selecting Frequency Starting operationYES TX Freq Standard type Netherlands type Special typeJ3E Direct frequency entryITU telephony channels SSB Custom channelsITU Telex channels Using the handset Tuning the antennaMonitoring transceiver output power TransmittingDistress Call on 2182 kHz Reducing transmitter powerDistress calls and Distress message Distress frequenciesDSC Distress Calling Event of Antenna Coupler FailureReceiving Squelch control Frequency ScanNoise blanker NB Channel scanITU channels Frequency SweepTelex Communication Optional DevicesRemote Station IntercomSetting Page Page This page is intentionally left blank Diagnostic Test Testing the transmitter with a dummy antennaWeekly Checks Page LCD/Keyboard Test & ROM Version No. Confirmation Competent technicians only Antenna Coupler TestMaintenance Page Troubleshooting List For qualified personnel only TroubleshootingTrouble Probable Cause Remedy Replacing Fuses Error IndicationThis page is intentionally left blank Appendix MF band working carrier frequencies ref. US CFR 47 Part CH no MF band SSB working carrier frequenciesFollowing frequencies are factory programmed MHz ITU SSB carrier frequencies ITU RR AppendixAP.5 12/16 MHz ITU SSB carrier frequencies ITU RR Appendix AP.7 MF Band Telex Frequency Table Telex ChannelsITU RR Appendix MHz Band ITU Nbdp Telex Frequency TableAP.10 AP.11 12/16 MHz Band ITU Nbdp Telex Frequency Table AP.13 18/19 MHz Band ITU Nbdp Telex Frequency Table AP.15 22, 25/26 MHz Band ITU Nbdp Telex Frequency Table