Chapter 3 CHANGING SYSTEM
SETTING
3.1 SYSTEM SETUP
1.While pressing and holding down the [RCL] key, turn on the power. Release the [RCL] key when the “MEMO” appears on the display.
System code
Setting value
MEMO
2.Turn the FREQ/CH control to select a desired code number.
3.Press the [RCL] key, enter desired setting by a numeral key, then press the [ENT] key.
4.To change setting for another code, repeat steps 2 and 3.
5.Turn off the power, then turn it on.
3.2 CUSTOMIZING BY OPERATOR
The operator can customize the parameters for scan, sweep and squelch function. The table below shows the system codes and their function, setting range and factory setting.
Code | Function, Setting |
9918 | Key response |
| Turns on/off key beep which sounds when wrong key is operated. |
| 0: OFF |
| 1: ON (Factory Setting) |
9919 | Noise blanker activation |
| Turns on/off noise blanker. |
| 0: OFF |
| 1: ON (Factory Setting) |
9920 | AGC activation |
| Turns on/off AGC. ON/OFF automatically activates or deactivates AGC |
| depending on class of emission. |
0: OFF
1: ON
2: MODE (Factory Setting)