Furuno FS-1562-15, FS-1562-25 manual

Page 36

 

 

 

 

 

 

Item

Check Point

Remedy/Remarks

 

 

Power cable

Check for loosened or corroded

Clean and tighten.

 

 

 

connection at power terminals.

 

 

 

 

 

 

 

 

Battery

Check that the battery is fully charged.

If discharged, charge.

 

 

 

 

 

 

 

Feeder (coax

Check for physical damage.

Replace if damaged.

 

cable, control

 

 

 

 

cable)

 

 

 

 

PCB connection

Check that jumper cables between boards

Reconnect loosened connections

 

 

 

are firmly connected.

of jumper cables.

 

 

 

 

 

 

 

Microphone

Check that jumper cables between boards

Fasten if loosened.

 

 

 

are firmly connected.

 

 

 

 

 

 

 

 

 

 

 

 

-4.6-

Image 36
Contents Page T 9 9 Safety Instructions Do not disassemble or modify the equipment List of Contents Features IntroductionSpecifications of MF/HF Radiotelephone model FS-1562 GeneralReceiver Operation Front View of Transceiver Unit Rotary controlsKeys Page Power Supply Unit AC and DC power switchesFuses Starting operation Selecting FrequencyTX Freq Standard type Netherlands type Special type YESDirect frequency entry J3ECustom channels ITU telephony channels SSBITU Telex channels Tuning the antenna Using the handsetMonitoring transceiver output power TransmittingReducing transmitter power Distress Call on 2182 kHzDistress frequencies Distress calls and Distress messageEvent of Antenna Coupler Failure DSC Distress CallingReceiving Frequency Scan Squelch controlNoise blanker NB Channel scanFrequency Sweep ITU channelsOptional Devices Telex CommunicationIntercom Remote StationSetting Page Page This page is intentionally left blank Diagnostic Test Testing the transmitter with a dummy antennaWeekly Checks Page LCD/Keyboard Test & ROM Version No. Confirmation Antenna Coupler Test Competent technicians onlyMaintenance Page Troubleshooting Troubleshooting List For qualified personnel onlyTrouble Probable Cause Remedy Error Indication Replacing FusesThis page is intentionally left blank Appendix MF band working carrier frequencies ref. US CFR 47 Part MF band SSB working carrier frequencies CH noMHz ITU SSB carrier frequencies ITU RR Appendix Following frequencies are factory programmedAP.5 12/16 MHz ITU SSB carrier frequencies ITU RR Appendix AP.7 Telex Channels MF Band Telex Frequency TableMHz Band ITU Nbdp Telex Frequency Table ITU RR AppendixAP.10 AP.11 12/16 MHz Band ITU Nbdp Telex Frequency Table AP.13 18/19 MHz Band ITU Nbdp Telex Frequency Table AP.15 22, 25/26 MHz Band ITU Nbdp Telex Frequency Table