Bogen UTI312 specifications Feature Code Data Default

Page 24

Feature

Feature

Code

Data

Default

 

Code Call Zone Group

*94

Zones

All-Call

 

Code Call Disable

040

 

040

 

Code Call Pattern

041

 

 

Code Call

Code Call Echo

042

 

 

 

Code Call 1 Play

043

 

043

 

Code Call 1 Repeat

044

 

 

 

Code Call 2 Repeat

045

 

 

 

 

 

 

 

 

 

 

 

 

Special Zone

Auto Select Zone Group

*96

Zones

No Zones

Groups

All-Call Zone Group

*97

Zones

All Zones

 

 

 

 

 

 

 

 

 

 

 

Zone Group 1

*01

Zones

None

 

Zone Group 2

*02

Zones

None

 

Zone Group 3

*03

Zones

None

 

Zone Group 4

*04

Zones

None

 

Zone Group 5

*05

Zones

None

 

Zone Group 6

*06

Zones

None

 

Zone Group 7

*07

Zones

None

 

Zone Group 8

*08

Zones

None

 

Zone Group 9

*09

Zones

None

 

Zone Group 10

*10

Zones

None

 

Zone Group 11

*11

Zones

None

Paging Zone

Zone Group 12

*12

Zones

None

Groups

Zone Group 13

*13

Zones

None

 

Zone Group 14

*14

Zones

None

 

Zone Group 15

*15

Zones

None

 

Zone Group 16

*16

Zones

None

 

Zone Group 17

*17

Zones

None

 

Zone Group 18

*18

Zones

None

 

Zone Group 19

*19

Zones

None

 

Zone Group 20

*20

Zones

None

 

Zone Group 21

*21

Zones

None

 

Zone Group 22

*22

Zones

None

 

Zone Group 23

*23

Zones

None

 

Zone Group 24

*24

Zones

None

 

 

 

 

 

 

 

 

 

 

 

Override Disable

070

 

 

 

Override Enable

071

 

071

 

Tone Trigger 1 Disable

072

 

 

 

Tone Trigger 1 Enable

073

 

073

 

Tone Trigger 2 Disable

074

 

 

 

Tone Trigger 2 Enable

075

 

075

AUX Relay

Page Disable

076

 

 

Page Enable

077

 

077

 

 

 

Night Ring Disable

078

 

 

 

Night Ring Enable

079

 

079

 

Delay

080

 

 

 

No Delay

081

 

081

 

Priority-Driven

082

 

 

 

Event-Driven

083

 

083

 

 

 

 

 

24

Image 24
Contents Installation and Use Manual UL Approved Contents Introduction UTI312 Front Panel with ZX3 Installed UTI312 Callouts Panel DescriptionsZX3 Callouts Installation Rack Mounting, Recessed for Wire AccessWall Mounting Rack Mounting, FlushTelephone Interface Wiring Connections & Setup Telephone System ConnectionsPBX Analog Station Port PBX Loop Start Trunk Port PBX Ground Start Trunk PortTrunk Disconnect PBX Page Port ContactPBX Page Port VOX Override Input 90V Night Ring InputOther Connections Night Ringer ContactTone Trigger Inputs 1 Background Music InputsZX3 Power Supply Output ZX3 Module ConnectionsZX3 Module Paging Output Connections ZX3 AUX ContactsControls Features & Operation ZonesPaging Zone Groups All-Call Zone GroupAuto Select Zone Group Override Zone Group & ToneNight Ring Zone Group & Tone Tone Trigger 1 & 2 Zone Groups & TonesCode Call Zone Group & Tones AUX Relay ContactFlexible Dialing Confirmation ToneTimers Setup ToneReset Default Values Dialing Time-outProgram. See the Feature Codes & Defaults charts System ProgrammingTone Zone Groups Code CallingPattern Code Call Echo Code CallEvent Enable/Disable Event-Driven/Priority-Driven ModeDelay/No Delay Priority-Driven Mode Issues Example 1 Emergency Tone/Emergency Announcement BypassExample 2 Strobes Flash to Announce Night Ring Example 3 Message Playback Following ToneFlexible Dialing Reference Chart Feature Codes & Defaults Trunk DisconnectFeature Code Data Default Renumber Zone Feature Code Test Mode Specifications Block Diagram, UTI312 Block Diagram, ZX3 Limited Warranty Page Spring Street, Ramsey, NJ 07446, U.S.A