Bogen UTI312 Telephone Interface Wiring Connections & Setup, Telephone System Connections

Page 7

Telephone Interface

Wiring Connections & Setup

Telephone System Connections

The UTI312 connects to virtually any telephone system: PBX station lines and CO lines, PBX loop start trunk ports, PBX ground start trunk ports, and page ports.

Interface installation consists of setting the slide switches and connecting with modular (RJ11) telephone plugs. Refer to the appropriate procedure in this section to connect the UTI312 to the telephone system.

Note: In all cases, make sure that power to the UTI312 is disconnected before performing the installation.

PBX Analog Station Port

In this configuration, the unit answers immediately upon detecting a ring. As soon as it answers, the default timer andVOX timer are started.The default timer determines the maximum length of any page.TheVOX timer repeatedly resets as long as audio is detected on the line. If no audio is detected within the VOX time period, then the page will end. If audio continues to be detected, then the default timer will control page length.

The unit will also immediately disconnect if a loss of loop current CPC (Calling Party Disconnect) is detected.

Make sure that the power is off and all connections are completed before proceeding. Move the interface slide switch on the UTI312 to STATION. The other interface slide switch is not used and can be in any position. Use a modular telephone cord (minimum 2-conductor) to connect the UTI312 Station Port RJ11 to the phone system. The center two conductors are Tip and Ring and are not polarity sensitive (see below). Set Default and VOX timers (see System Programming).The timers can be independently inhibited.

Note:The default time-out is factory set to 30 seconds, and the VOX time-out is set to 6 seconds. If both the default and VOX timers are inhibited, the only way to release the system from the station line is through the use of a Calling Party Control (CPC) pulse.

7

Image 7
Contents Installation and Use Manual UL Approved Contents Introduction Panel Descriptions UTI312 Front Panel with ZX3 Installed UTI312 CalloutsZX3 Callouts Rack Mounting, Flush InstallationRack Mounting, Recessed for Wire Access Wall MountingTelephone System Connections Telephone Interface Wiring Connections & SetupPBX Analog Station Port PBX Ground Start Trunk Port PBX Loop Start Trunk PortPBX Page Port Contact Trunk DisconnectPBX Page Port VOX 90V Night Ring Input Override InputBackground Music Inputs Other ConnectionsNight Ringer Contact Tone Trigger Inputs 1ZX3 AUX Contacts ZX3 Power Supply OutputZX3 Module Connections ZX3 Module Paging Output ConnectionsControls All-Call Zone Group Features & OperationZones Paging Zone GroupsTone Trigger 1 & 2 Zone Groups & Tones Auto Select Zone GroupOverride Zone Group & Tone Night Ring Zone Group & ToneConfirmation Tone Code Call Zone Group & TonesAUX Relay Contact Flexible DialingDialing Time-out TimersSetup Tone Reset Default ValuesSystem Programming Program. See the Feature Codes & Defaults chartsEcho Code Call Tone Zone GroupsCode Calling Pattern Code CallEvent-Driven/Priority-Driven Mode Event Enable/DisableDelay/No Delay Example 3 Message Playback Following Tone Priority-Driven Mode IssuesExample 1 Emergency Tone/Emergency Announcement Bypass Example 2 Strobes Flash to Announce Night RingFlexible Dialing Reference Chart Trunk Disconnect Feature Codes & DefaultsFeature Code Data Default Renumber Zone Feature Code Test Mode Specifications Block Diagram, UTI312 Block Diagram, ZX3 Limited Warranty Page Spring Street, Ramsey, NJ 07446, U.S.A