Bogen UTI312 specifications Installation, Wall Mounting, Rack Mounting, Flush

Page 6

Installation

Mounting

Wall Mounting

Mounting to a plywood backboard or studs:

1. On each side remove the four screws in the corners and use them to attach the mounting flanges so that the flanges are facing the rear of the unit.

2.Hold the unit level against the surface to which it will be mounted.

3.Using the keyholes, mark on the mounting surface where the mounting screws (not included) should be positioned.

4.Set the unit aside and install the screws leaving about 1/4" of the screws sticking out of the surface.

5.Slip the unit over the screws through the keyholes and let the unit rest on the screws.Tighten screws snugly.

Rack Mounting, Flush

Mounting flush to a rack:

1. On each side remove the four screws in the corners and use them to attach the mounting flanges so that the flanges are facing the front of the unit.

2.Attach unit to rack with 4 rack screws (not supplied). Do not use keyholes for mounting to a rack.

Rack Mounting, Recessed for Wire Access

Recessed in a rack to allow for top or bottom wire entry:

1. On each side remove the four screws in the corners and use them to mount the mounting flanges so that the flanges are protruded from the front of the unit.This recess allows enough space for wire access from top or bottom.

2.Attach unit to rack with 4 rack screws (not supplied). Do not use keyholes for mounting to a rack.

ZX3 Module Installation & Jumper Selections

The UTI312 module bay can accommodate up to four ZX3 modules. Each ZX3 module has 3 zone outputs giving the UTI312 a capacity of up to 12 paging zones.

Each module slot is marked on the lower left hand corner indicating which zones correspond with each slot.

To install, first select each zone’s Music Bus A or B or (no music) using the jumpers, then slide the ZX3 module into the card guides and push the module all the way home. Secure with mounting screws.

Wall Mounting

Rack Mounting, Flush

Rack Mounting,Wire Access

ZX3 BGM Jumper Selections

6

Image 6
Contents Installation and Use Manual UL Approved Contents Introduction UTI312 Front Panel with ZX3 Installed UTI312 Callouts Panel DescriptionsZX3 Callouts Wall Mounting InstallationRack Mounting, Recessed for Wire Access Rack Mounting, FlushTelephone Interface Wiring Connections & Setup Telephone System ConnectionsPBX Analog Station Port PBX Loop Start Trunk Port PBX Ground Start Trunk PortTrunk Disconnect PBX Page Port ContactPBX Page Port VOX Override Input 90V Night Ring InputTone Trigger Inputs 1 Other ConnectionsNight Ringer Contact Background Music InputsZX3 Module Paging Output Connections ZX3 Power Supply OutputZX3 Module Connections ZX3 AUX ContactsControls Paging Zone Groups Features & OperationZones All-Call Zone GroupNight Ring Zone Group & Tone Auto Select Zone GroupOverride Zone Group & Tone Tone Trigger 1 & 2 Zone Groups & TonesFlexible Dialing Code Call Zone Group & TonesAUX Relay Contact Confirmation ToneReset Default Values TimersSetup Tone Dialing Time-outProgram. See the Feature Codes & Defaults charts System ProgrammingPattern Code Call Tone Zone GroupsCode Calling Echo Code CallEvent Enable/Disable Event-Driven/Priority-Driven ModeDelay/No Delay Example 2 Strobes Flash to Announce Night Ring Priority-Driven Mode IssuesExample 1 Emergency Tone/Emergency Announcement Bypass Example 3 Message Playback Following ToneFlexible Dialing Reference Chart Feature Codes & Defaults Trunk DisconnectFeature Code Data Default Renumber Zone Feature Code Test Mode Specifications Block Diagram, UTI312 Block Diagram, ZX3 Limited Warranty Page Spring Street, Ramsey, NJ 07446, U.S.A