Tone Zone Groups

In addition to paging zone groups, there are five additional zone groups, each with an associated tonal function.These are Override zone group, Night Ring zone group,Tone Trigger 1 zone group,Tone Trigger 2 zone group, and Code Call zone group. By default, these zone groups are set to all zones.

Each is programmed in the same manner as the paging zone groups, only with a different feature code. For example, to program zones to the Tone Trigger 1 zone group, dial the Tone Trigger 1 zone group feature code (*91), followed by the zone numbers to be included in the zone group, followed by the # key to store the data.

To return these zone groups to All-Call, dial their respective feature code followed by 00# (*9700#).

To clear zones from these zone groups, dial the feature code for that particular

zone group followed by the # sign. For example, to clear all zones from Tone Trigger 1 zone group, dial *91#.

What differentiates these zone groups from the paging zone groups is the tone associated with them. The tone for each of these zone groups can also be programmed along with the zones. For example, to program Tone Trigger 1 for zone 1, zone 3, zone 5, and zone 7 with the chime follow contact tone (feature code 029), dial *9101030507#029#.

For each particular zone group’s default settings and options, refer to the Feature Codes and Defaults table on pages 23-26.

Code Calling

Code calling triggers a series of chime tones to the Code Call zone group. There are two types of code calling: pattern and echo.

Pattern Code Call

Pattern code calling sounds a factory-set pattern of chime tones in response to a DTMF selection by the caller. There are 10 patterns available. To program the Code Call zone group for pattern code calling, dial feature code 041 followed by the # key.

Echo Code Call

Echo code calling sounds chime tones that correspond to a 2-digit entry made by the caller with each digit representing the number of chimes.To program the Code Call zone group for echo code calling, dial feature code 042 followed by the # key.

Code Call Playback

By default, code calling triggers a series of chime tones to a zone or zone group one time (Code Call 1 Play). Code calling can be programmed to playback the series of chime tones once (Code Call 1 Repeat) or twice (Code Call 2 Repeat) for a total of three executions. To program code calling for 1 Repeat or 2 Repeat, dial the feature code (044 or 045) followed by the # key. Ex.: 044# for Code Call 1 Repeat.

The code call feature can be enabled and disabled without losing any of the programmed data associated with it.

DTMF Block

DTMF Block, to suppress DTMF tone pass-through, can be enabled (feature code 068) or disabled (feature code 069).

Timers

Default Timer

To change the default timer, enter the feature code 050 and the new 2-digit number corresponding to the time desired followed by the # key.The 2-digit number represents default time in multiples of 10 seconds. (Example: 03

=30 seconds; 12 = 120 seconds.) Ex.: 05003# for 30 seconds. If you wish to inhibit the default timer, enter "00" for the time data.

VOX Timer

To set the time duration for the VOX time-out, enter the feature code 051 followed by a single digit from 1 to 9, corresponding to 1 to 9 seconds, followed by the # key. Ex.: 0515# for 5 seconds. To inhibit the timer, enter the Feature Code followed by "0".

Note: If both the default and VOX timers are inhibited, the only way to release the UTI312 from a station line is through the use of a Calling Party Control (CPC) pulse of 300 ms or longer.

19

Image 19
Contents Installation and Use Manual UL Approved Contents Introduction Panel Descriptions UTI312 Front Panel with ZX3 Installed UTI312 CalloutsZX3 Callouts Rack Mounting, Flush InstallationRack Mounting, Recessed for Wire Access Wall MountingTelephone System Connections Telephone Interface Wiring Connections & SetupPBX Analog Station Port PBX Ground Start Trunk Port PBX Loop Start Trunk PortPBX Page Port Contact Trunk DisconnectPBX Page Port VOX 90V Night Ring Input Override InputBackground Music Inputs Other ConnectionsNight Ringer Contact Tone Trigger Inputs 1ZX3 AUX Contacts ZX3 Power Supply OutputZX3 Module Connections ZX3 Module Paging Output ConnectionsControls All-Call Zone Group Features & OperationZones Paging Zone GroupsTone Trigger 1 & 2 Zone Groups & Tones Auto Select Zone GroupOverride Zone Group & Tone Night Ring Zone Group & ToneConfirmation Tone Code Call Zone Group & TonesAUX Relay Contact Flexible DialingDialing Time-out TimersSetup Tone Reset Default ValuesSystem Programming Program. See the Feature Codes & Defaults chartsEcho Code Call Tone Zone GroupsCode Calling Pattern Code CallEvent-Driven/Priority-Driven Mode Event Enable/DisableDelay/No Delay Example 3 Message Playback Following Tone Priority-Driven Mode IssuesExample 1 Emergency Tone/Emergency Announcement Bypass Example 2 Strobes Flash to Announce Night RingFlexible Dialing Reference Chart Trunk Disconnect Feature Codes & DefaultsFeature Code Data Default Renumber Zone Feature Code Test Mode Specifications Block Diagram, UTI312 Block Diagram, ZX3 Limited Warranty Page Spring Street, Ramsey, NJ 07446, U.S.A