Bogen UTI312 specifications Introduction

Page 4

Introduction

The UTI312 Paging System is an expandable multi-zone paging and signaling system.The system provides the following features and functions:

Voice Channel

Expandable to 12 zones

Telephone interfaces:

-loop start trunk

-ground start trunk

-station access (analog ring-up)

-page port contact closure activation

-page port voice activation

Override paging (using loop start trunk or page port contact closure activation) zone group

Audio output with level control per zone can provide audio for 150 Bogen one-way self-amplified speakers; also compatible with 70V amp inputs

Zone activity LEDs

Zone contact closure

Pre-Announce/Confirmation Tone

Adjustable Automatic Level Control with threshold and active indicator

Background Music

Two high-impedance transformer isolated BGM inputs

Individual volume controls

Background music source selectable per zone

Stereo combining inputs

Signaling Tones

Night Ringer (90V and contact closure activation) with zone group

Two Tone Triggers (tone and duration selectable, closure activated) with individual zone groups

Code Calling with zone group

Other Features

Flexible dialing plan for zone numbers

2 to 5 digit dialing plans

24 zone groups

C-form contact set with programmable activation events

Non-volatile memory for setup data

Setup Tone to assist in volume setting, etc.

Pluggable terminal strips

Microcontroller-based operation

DTMF setting of operating parameters

Package Contents

(1) UTI312

(1) Installation and Use Manual

(1) ZX3 Module (installed)

4

Image 4
Contents Installation and Use Manual UL Approved Contents Introduction Panel Descriptions UTI312 Front Panel with ZX3 Installed UTI312 CalloutsZX3 Callouts Installation Rack Mounting, Recessed for Wire AccessWall Mounting Rack Mounting, FlushTelephone System Connections Telephone Interface Wiring Connections & SetupPBX Analog Station Port PBX Loop Start Trunk Port PBX Ground Start Trunk PortPBX Page Port Contact Trunk DisconnectPBX Page Port VOX Override Input 90V Night Ring InputOther Connections Night Ringer ContactTone Trigger Inputs 1 Background Music InputsZX3 Power Supply Output ZX3 Module ConnectionsZX3 Module Paging Output Connections ZX3 AUX ContactsControls Features & Operation ZonesPaging Zone Groups All-Call Zone GroupAuto Select Zone Group Override Zone Group & ToneNight Ring Zone Group & Tone Tone Trigger 1 & 2 Zone Groups & TonesCode Call Zone Group & Tones AUX Relay ContactFlexible Dialing Confirmation ToneTimers Setup ToneReset Default Values Dialing Time-outProgram. See the Feature Codes & Defaults charts System ProgrammingTone Zone Groups Code CallingPattern Code Call Echo Code CallEvent-Driven/Priority-Driven Mode Event Enable/DisableDelay/No Delay Priority-Driven Mode Issues Example 1 Emergency Tone/Emergency Announcement BypassExample 2 Strobes Flash to Announce Night Ring Example 3 Message Playback Following ToneFlexible Dialing Reference Chart Feature Codes & Defaults Trunk DisconnectFeature Code Data Default Renumber Zone Feature Code Test Mode Specifications Block Diagram, UTI312 Block Diagram, ZX3 Limited Warranty Page Spring Street, Ramsey, NJ 07446, U.S.A