ENGLISH
TROUBLESHOOTING
SYMPTOM | POSSIBLE CAUSE | SUGGESTED REMEDY |
|
|
|
Pilot will not light | Gas supply off | Check main / unit gas valves |
|
|
|
| Air in lines | Turn pilot valve on. Attempt to |
|
| light pilot every 15 sec. |
| Pilot valve not on | Turn pilot valve on / adjust |
|
|
|
Burners won’t light | Gas supply off | Check main / unit gas valves |
|
|
|
| Air in lines | Turn gas valve on. Attempt to |
|
| light pilot every 15 sec. |
| Pilot burner not lit | Turn off gas - allow unit to |
|
| vent for 5 minutes. Turn gas |
|
| back on and light pilot |
|
|
|
One burner assembly | Control not on | Turn control knob to ON |
won’t light |
| Set to desired setting when lit |
| Water in burner | Remove burner and dry |
|
| thoroughly |
| Damaged gas control valve, | Contact Authorized Wells |
| burner or other internal | Service Agency for repairs |
| component |
|
Portions of a burner won’t light or | Burner wet or flame opening(s) | Clean and dry burner |
have erratic flame | clogged |
|
Burner not hot enough | Temperature control not set | Adjust for desired temperature |
|
|
|
| Shutter or nozzle out of | Contact qualified technician for |
| adjustment | adjustment |
| Damaged gas control valve, | Contact Authorized Wells |
| burner or other internal | Service Agency for repairs |
| component |
|
|
|
|
NOTE: There are no user serviceable components in the burner assemblies or in the control valves. In all cases of damage or malfunction, contact your Authorized Wells Service Agency for repairs.
164 307737 OpManual for HDCR-Series Char-Rock Broilers
12