2Wire HDCR-1230G, HDCR-4830G, HDCR-2430G SET GAS Pressure, SET Pilot Flame, Adjust Burner Flame

Page 9

164 307737 OpManual for HDCR-Series Char-Rock Broilers

SET GAS PRESSURE:

Gas pressure regulator is factory set.

SET PILOT FLAME:

Remove all burner control knobs, then remove the front panel. Remove grates.

The pilot adjustments are near the control valve for each set of burners.

Using a small, flat-blade screwdriver, turn the screw clockwise to decrease the flame size, or counter-clockwise to increase the flame size.

Adjust the pilot flame to 1/4” high. Test for operation: all sections of the burner must light without undue delay. Drafty conditions may require a higher flame to allow the pilot to remain lit.

Replace the grates, front panel and all knobs before returning the unit to service.

ADJUST BURNER FLAME:

Remove all burner control knobs, then remove the front panel. Remove grates and radiants.

Turn an individual burner on.

Loosen the locking screw on the shutter.

Turn the shutter to admit more or less air as required. Adjust the air shutter until the flame is mostly blue in color.

Tighten the locking screw when finished. Replace tall grates and radiants, the front panel and all knobs before returning the unit to service.

BURNER

PILOT

FLAME

FLAME

ADJUST

ADJUST

 

LESS

 

AIR

 

SHUTTER

 

MORE AIR

LESS

 

LOCKING

FLAME

SCREW

 

 

MORE

 

FLAME

BURNER

PILOT

FLAME

CONTROL

KNOB

ADJUST

 

Fig. 3 Adjustments

IMPORTANT:

Adjustments must be performed by a qualified technician only.

IMPORTANT:

The appliance is shipped from the factory equipped for natural gas and adjusted for sea level to 2000 feet elevation.

For conversion to LP / Propane, or for operation above 2000 feet elevation, contact your Authorized Wells Service Agency.

ENGLISH

7

Image 9
Contents Important do not Discard this Manual 164English Model Style Fuel Manifold Pressure 164 307737 OpManual for HDCR-Series Char-Rock Broilers 164 307737 OpManual for HDCR-Series Char-Rock Broilers English Risk of Injury Fire Explosion HazardSupplied Regulator GAS SHUT-OFF Valve Vent Installing the GAS GriddleAdjust Burner Flame SET GAS PressureSET Pilot Flame English Cooking Recommendations OperationFire Hazard CleaningBurn Hazard PreparationFire Hazard Cleaning BurnersSymptom Possible Cause Suggested Remedy TroubleshootingWells Bloomfield, LLC Pour Votre Sécurité AvertissementImportant NE PAS Jeter CE Guide Introduction Français Français Tourner Pour Régler LA Hauteur ’INCENDIE ET ’EXPLOSION ’INCENDIE AvertissementRéglage DE Pression DU GAZ Réglage DE LA Veilleuse D’ALLUMAGERéglage DE LA Flamme DE Brûleur 164 307737 OpManual for HDCR-Series Char-Rock Broilers Fonctionnement Recommandations pour la cuissonPréparation BrûluresFréquence UstensilesInstructions Pour LE Nettoyage a continué Conseils Pour LE Dépannage Wlees Bloomfield, LLC Renseignements À Fournir AU Service APRÈS-VENTEGenuin e Parts