NuTone Nm100WH installation instructions Removing the Old System, Installing the Rough-In

Page 3

model NM100WH

Removing the Old System

Prior to removing the existing intercom system make sure all power is turned off at the intercom location. Remove the screws from the intercom master and while removing the intercom, make sure to carefully label each wire with its corresponding room location. Disconnect all the remote station and door station wires from the master. Then carefully remove the existing wall housing and transformers.

If the existing system was not working prior to replacement, check each wire run between the remote stations and master for shorts and wiring integrity. If one of these remote station to master wire runs has a short, re-run that wire prior to installing the NM100. When replacing NuTone 3 wire cable runs, use NuTone IWA3 cable. When replacing NuTone or M&S 4 wire cable runs, use NuTone NW4S cable.

Note: if you encounter 120VAC running through the existing rough- in, have a qualified electrician reroute the 120VAC around the rough-in.

If you encounter a remote transformer, an additional electrical run may have to be made by a qualified electrician to power the master station and/or optional CD player. Also check to make sure that the area around the housing is clear of any additional 120VAC runs or other obstructions.

Installing the Rough-In

The NWH300 and NWH300C rough-ins are designed for 16” on center studs. In retrofit applications you may encounter stud spacing that varies from this standard. Use the NWH300 rough-in when you are replacing an existing system with an intercom only system. The NWH300C rough-in is used for combination systems only that use the NM100 master and the optional NC300 6-disc CD player.

Locate the NWH300 or the NWH300C rough-ins. The rough-in must be positioned so that the transformers are on the bottom of the rough-in as shown in the figure below.

Page 

If you are replacing the existing master only system with a combination NM100 master and NC300 CD changer you will have to cut the rough-in opening larger to accommodate the larger rough- in. Prior to making the cutout check the stud cavity for obstructions or items in the wall that may prevent the transformers from fitting in the wall. The NWH300 and NWH300C transformers drop in from the bottom of the rough-in. Please refer to the next figure for rough-in placement.

Connect the existing, dedicated 120VAC/60Hz line with ground connection from the power panel to the rough-in as shown below. The NM100 requires a dedicated power source to assure no interference from other equipment caused by looped power circuits. The ground is necessary for proper radio reception.

Place transformer enclosure from the inside of the wall housing into the transformer enclosure opening at the bottom of the rough-in as shown below. Do not run the 120VAC through the rough-in.

Image 3
Contents System Installation Develop the Job Estimate InstallationRemoving the Old System Installing the Rough-InReplacing the Room Stations NM100 NuTone Wire function Connection IWA3 CableDoor Stations Installing the Chime ModuleInstalling the NC300 CD changer Outdoor Remote StationsInstalling the NM100 Connecting the Antenna Door Release OptionsDoor or Gate Release Mechanism Panic Interface with Security System TestingAppendix b M&S systems Model NM100WH Avertissement Lire CES Directives ET LES ConserverEstimation DES Travaux InstallationEnlèvement DE L’ANCIEN Système D’INTERPHONE Installation DU BoîtierRemplacement DES Stations DES Pièces NM100Câble Nutone Fonction DU FIL Connexion IWA3 Stations DE Porte Installation DU Module DE CarillonInstallation DU Changeur DE CD NC300 Stations À Distance ExtérieuresInstallation DU NM100 Connexion DE L’ANTENNE Options DE Serrure ÉlectriqueSerrure Électrique DE Porte OU DE Barrière Test Annexe a Systèmes NutoneInterface D’URGENCE À Système DE Sécurité Annexe B Systèmes M&S Modèle NM100WH Advertencia PrecauciónElaboración DEL Estimado DE Trabajo InstalaciónInstalación DEL Empalme Cómo Retirar EL Sistema AntiguoReemplazo DE LAS Estaciones DE Habitación Conexión Cable IWA3 FunciónNutone DEL Cable Instalación DEL Módulo DEL Timbre Estaciones Remotas Para ExterioresEstaciones DE Puerta Fuente DE Música ExternaInstalación DEL NM100 Conexión DE LA Antena Opciones DE Liberación DE PuertaMecanismo DE Liberación DE Puerta O Reja Apéndice a Sistemas Nutone PruebaApéndice B Sistemas M&S Modelo NM100WH Model NM100WH Adaptables a UN Propósito EN Particular Merchantability or Fitness for a Particular Purpose