model NM100WH
Installing the NM100
The NM100 ships configured for a
Place the jumpers you just disconnected in the
Suspend the master unit from the
Page
If the NM100 system has more than 9 remote stations, some remote selector switches will control two remote stations. Connect each Green wire (except patio/outdoor remote Green) to a single green terminal on the master. Each numbered Green terminal corresponds to a remote station selector switch. Note: No more than 2 Green wires can be connected to any Green terminal and not to exceed 15 speakers for the
Connect the green wire(s) from the outdoor remote station(s) to the Patio green terminal. Connect the outdoor remote Black wire(s) to the patio Black terminal. Note: Only two outdoor remote stations can be connected to the patio terminals. Connect the Red wire with the other Red wires to the Red terminal. Connect the White wire with the other White wires to the White terminal. Refer to the figure shown below for wire placement.
Connect the red and black wires of the door station cables (NW4S) to the red and black door station terminals on the NM100 master as shown in the next figure. When using the NW4S shielded wire, insulate the bare wires using some of the jacket material to prevent shorting to the circuit board. Connect this wire to terminal labeled shield. Connect all orange wires from the door stations to the common terminal on the NA3003C or NA3008C chime module. Connect each yellow wire to a note sleection terminal. (Do not connect more than one yellow wire per note terminal).
Plug in the modular chime plug to the 4 pin connector labeled as CHIME on the NM100 master unit as shown in the next figure.