NEC ND-70895 (E) system manual Asydn

Page 65

COMMANDS

ASYDN

 

SYSTEM

 

 

BIT

 

 

 

 

 

 

SYSTEM

DATA

CORRESPONDING

 

 

 

 

 

 

DATA

 

 

 

 

 

 

DATA

(DATA)

 

DATA

 

 

 

 

 

 

INDEX

 

 

 

 

SYSTEM DATA CONTENTS

(MDATA)

TYPE

00 – FF

 

 

 

 

 

 

(INDEX)

 

 

 

 

 

 

 

 

 

(SYS)

(Hex)

DATA

 

 

 

 

 

 

 

 

0 – 1535

 

BIT

 

 

 

 

 

 

 

 

0/1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

b0

 

Network Data Memory (NDM) usage. Assign

 

 

 

 

 

 

b1

 

data “1 (the memory block is used)” for the

 

 

 

 

 

 

 

corresponding memory block.

 

 

 

 

 

 

b2

 

 

 

 

 

 

 

 

bit

Memory Block

 

 

 

 

 

 

b3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

514

01

 

 

 

b0

 

Memory Block #0

 

 

 

 

 

b4

 

 

 

 

 

 

 

 

 

 

b1

 

Memory Block #1

 

 

 

 

 

 

 

b5

 

 

 

 

 

 

 

b2

 

Memory Block #2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

b6

 

b3

 

Memory Block #3

 

 

 

 

 

 

 

 

 

b4

 

Memory Block #4

 

 

 

 

 

 

 

b7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

b0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

b1

 

Set up Fusion Point Code (FPC) of Node which

 

 

 

 

 

 

 

 

 

 

 

 

 

 

b2

 

 

 

 

 

 

 

basic VNDM is mounted on. (1~253)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

533

 

 

 

b3

 

 

 

 

 

 

 

 

 

 

b4

Note: OAI/ACD is available in used.

 

 

 

 

 

 

 

1

 

 

 

 

b5

 

 

 

VNDM = Variable Network Data

 

 

 

 

 

 

 

 

 

 

Memory

 

 

 

 

 

 

b6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

b7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

864

 

 

 

b3

 

Multiple IPs 0/1 = Out/In Service Note 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

b0

 

FLF Fusion Service

 

 

 

 

 

 

 

0/1 = Invalid/Valid Note 2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

b1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

b2

 

 

 

 

 

 

 

870

 

 

 

b3

 

 

 

 

 

 

 

 

 

 

 

b4

 

Not used

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

b5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

b6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

b7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Note 1: When the all Fusion nodes in the network are used for “MULTIPLE IPs”, this data may be assigned using

ASYDN.

Note 2: Available since the Series 7400 (Release 8) software.

ND-70895 (E)CHAPTER 4

Page 55

Revision 1.0

Image 65
Contents Stock # ND-70895 ENEC America, Inc Liability DisclaimerNEAX2400 IMX Issue No OAI System Manual NEAX2400 IMXTable of Contents ND-70895 Etable of Contents Page iii Revision List of Figures List of Tables This page is for your notes General How to Follow the ManualConfiguration of this manual is shown in Table Introduction Explains the outline of the OAI system System OutlineSystem Outline Block Concept of MSF Concept of TMF Concept of ACF Concept of TCF Concept of NTF 11 Concept of RCF 13 Concept of ATF Join of Facilities and Application System Configuration Symbol Symbol Name Circuit Card Remarks 15 IP Dual System Configuration Dual System Configuration of NEAX2400 IMX IMGCircuit Card Interface Conditions Interface with External ComputerThis page is for your notes Installation Procedure Cable Connections with External Computer System DATA=OVERRIDE/LOAD OAI Software InstallationChange system data written in DM Asyd SYS1INDEX513 Assign the system data written in LDMAsydl SYS1 INDEX512 Upgrading OAI System from NEAX2400 ICS to NEAX2400 IMX This page is for your notes This section explains the construction of each command CommandsConfiguration of Commands of the NEAX2400 IMX OAI System Configuration of Commands for OAI SystemThis section explains the commands in used in the OAI System CommandsInterrelation among OAI System Commands Type Aadt Assignment of Announcement/Dictation TrunksMsgt WaitAnnouncement/Dictation Trunk Data Assignment Table Disconnect Timer = Impossible = PossibleAmno Acno Assignment of Conversion Number DataLcno LrtdConversion Number Data Assignment Table Akyd Assignment of Key Data for Dterm MNO Amno Assignment of Monitored NumberNMI UCDMonitored Number Assignment Table Loac Aoac Assignment of OAI Access CodeKind OAI Access Code Data Assignment Table Aokc Assignment of OAI Key Code Kind = 1 OP-CODE = 128 ~ Kind = 2 OP-CODE = 192 ~ Related Commands List Up LokcOAI Key Code Data Assignment Table Operation Code Remarks Service Feature Index a Aspa Assignment of Specific Access CodeSida OAI Dial Number Batch Transfer TMFAsyd Assignment of System Data MTC Equipped capacity of the Common Memory CM 1 ~ 4 Mbyte System Data Assign TableCalled Number Display when forwarding to Attendant Console Calling and Intermediate Station Number indication = # key/* key No CPU Mounted Status of IP00/1Not mounted/Mounted System Data Assign Table HEX/ASCII Data BIT System Data Contents Lstn Dfln Display of Location Free NumberingPstn RSCAsydn Assignment of System Data in NDM Asydn Asydl Assignment of System Data into Local DM LDM Example Subnet Mask Example IP AddressDefault Gateway Address Office Data Design ASYD/ASYDL Procedure for Setting Basic Office Data for OAI SystemASYDL-SYS1 INDEX513 Hex LDM usageAokc AkydAoac AnpdProcedure for Setting Office Data for OAI Services Using Conditions Abnormal Sequence SYS1 Index B6 1 OAI service is not availableAssignment Asyd System Data Call ID Notification Smfn for Isdn Functional Outline Isdn Caller’s Number Information ≤ n ≤ TMM Text Mail ModuleFacsimile Mail Module FMMAbnormal Sequence NEAX2400 IMX DLC TSW SYS1 Index TCP/IP Address Assignment from MAT Functional Outline Index SYS1Name Display Functional Outline INDEX79 INDEX78INDEX241 Asyd SYS1 INDEX78Called party Catching call from other internal lineCcis B6 = 1 OAI Service is not in service B6 = 0 OAI Service is in serviceAsyd SYS1 Index B1 = 0 Name Display 8-digitOAI Fusion ASYDL/ASYDN Assignment of System Data Data for OAI FusionINDEX533 FPC number of the node that has the standard VndmMultiple IPs Functional Outline III III PBX Example of Use of Facility on Fusion Network This page is for your notes Maintenance Maintenance System Messages System Fault Contents of FaultSystem Message 4-R System Message 4-R TCP/IP Link Failure 1. Print-out FormatTCP/IP Link Failure NEC ESD= MIS ACD System Message 26-VLAN Interface Error Report= OAI Flow of Fault Repair Fault DiagnosisDiagnosis from System Messages Start Repairing Procedure for TCP/IP Link Failure Message 4-RND-70895 Echapter Revision This page is for your notes