2.1 Before Installing

4.Use 2-pair telephone cables when connecting Panasonic proprietary telephones (PTs). Use 1-pair telephone cables when connecting single line telephones (SLTs), data terminals, answering machines, computers, voice processing systems, etc.

5.Unplug the PBX from its power source when wiring, and plug the PBX back in only after all wiring is completed.

6.Mis-wiring may cause the PBX to operate improperly. Refer to Section 2, "Installation" when wiring the PBX.

7.If an extension does not operate properly, disconnect the telephone from the extension line and connect it again, or turn off the PBX using the power switch then turn it on again.

8.For safety purposes this unit is equipped with an earthed plug. If you do not have an earthed outlet, please have one installed. Do not bypass this safety feature by tampering with the plug.

9.Use twisted pair cable for outside (CO) line connection.

10.Outside (CO) lines should be installed with surge protectors. For details, refer to "2.4.1 Connecting Outside (CO) Lines", "2.2.8 Installing Surge Protector".

WARNING

Static-sensitive devices are used in this PBX. To protect printed circuit boards from static electricity, do not touch the connectors indicated below. To discharge static electricity from your body, touch ground or wear an earthing strap.

Side View

Warning: Static-sensitive connectors

Installation Manual

23

Image 23
Contents Advanced Hybrid System Installation ManualSystem Components Compatible Proprietary Telephones Abbreviations in this manualImportant Safety Instructions For users in Taiwan only PrecautionsFor users in New Zealand only For users in Australia onlyFor users in Finland, Norway and Sweden only For Future ReferenceHttp//doc.panasonic.de Introduction For Your SAFETY, Please Read the Following Text Carefully Precautions for Users in the United KingdomInstallation Manual Table of Contents Guide for KX-TE Maintenance Console Section System Outline System Highlights System HighlightsMain Unit Basic System ConstructionOutside CO Line System Connection DiagramGeneral Description SpecificationsCharacteristics System Data System CapacitySystem Capacity Maximum Cards and Terminal Equipment Max. Quantity Section Installation Installation Precautions Before InstallingBefore Installing Safety Installation InstructionsBefore Installing Unpacking Installing the Advanced Hybrid SystemNames and Locations Opening Covers Opening/Closing CoversClosing Covers Securing Cords To remove the rivet, use a screwdriver as shown below Connect the frame of the PBX to earth Connecting Frame EarthConnecting Backup Batteries Battery Rating 24 Ah Mounting on a Wooden Wall Wall MountingMounting on a Concrete or Mortar Wall Installing the Advanced Hybrid System Overview Installing Surge ProtectorInstallation Installation of an Earth Rod Outside InstallationInstalling the Advanced Hybrid System Location of Optional Service Cards Installing Optional Service CardsFunction Installing KX-TE82483 to KX-TES824Installing Optional Service Cards Installing KX-TE82480 to KX-TES824 Installing Optional Service Cards Installing Optional Service Cards Installing KX-TE82480 to KX-TEM824 Installing Optional Service Cards 4 8-Port SLT Extension Card KX-TE82474 Installing KX-TE82474 to KX-TES824Installing Optional Service Cards Installing KX-TE82474 to KX-TEM824 5 3-Port Caller ID Card KX-TE82493 6 4-Port Doorphone Card KX-TE82461 Message Expansion Card for DISA/UCD OGMs KX- TE82491 8 2-Channel Voice Message Card KX-TE82492 Connection Connecting Outside CO LinesConnecting Outside CO Lines Maximum Cabling Distance of Extension Wiring Twisted Cable Connecting ExtensionsConnecting Extensions Telephone Wiring Connecting Extensions in Parallel Maximum Cabling Distance Connecting Doorphones and Door OpenersConnecting Doorphones and Door Openers Installing the Doorphone KX-T30865Connecting Doorphones and Door Openers Connecting Doorphones KX-T30865 Connecting Door Openers Connecting Doorbell or Door Chime Connecting Doorbell or Door ChimeConnecting Peripherals Connecting PeripheralsPC/Printer via RS-232C PagerFor connecting a PC/printer with a 25-pin RS-232C connector Circuit Type Signal Name FunctionFor connecting a PC/printer with a 9-pin RS-232C connector PC via USB 1.1 interface Power Failure Connections Power Failure ConnectionsStarting the Advanced Hybrid System Starting the Advanced Hybrid SystemStarting the Advanced Hybrid System Starting the Advanced Hybrid System Section Guide for KX-TE Maintenance Console System Requirements Installing KX-TE Maintenance ConsoleInstalling KX-TE Maintenance Console on a PC Setting the Password and Password SecurityClick Maintenance Console Installing KX-TE Maintenance ConsoleSerial Interface Connection Installing the USB DriverConnection ConnectionWindows Windows 98SEWindows Me Click Continue Anyway Windows XPStarting KX-TE Maintenance Console for the first time Click Initialise Accessing PBX via Internal Modem→ KX-TE Maintenance Console Select Auto Tone or Auto Pulse for Dial TypeConnection Connection Section Troubleshooting Installation TroubleshootingCause Operation System Restart System Reset with System Data Clear Index Numerics Template for Wall Mounting Copyright