4.1 Troubleshooting
4.1.2Connection
Telephone cord connecting the PBX and a proprietary telephone (PT):
Can you dial an extension?
| No |
|
| CAUSE | SOLUTION | |||||
|
|
| ||||||||
|
|
|
|
|
|
|
| |||
The T/R pins are connected to the H/L | Use the correct cord (the | |||||||||
|
|
| ||||||||
|
|
| ||||||||
|
|
| pins. |
|
|
|
| inner 2 wires are for T/R and | ||
|
|
|
|
|
|
|
|
| the outer 2 wires are for H/L). | |
|
|
|
| H |
|
| H |
| ||
|
|
|
| T |
|
| T |
|
| |
|
|
|
| R |
|
| R |
|
| |
|
|
|
| L |
|
| L |
|
| |
|
|
|
|
|
|
|
|
|
| |
|
|
|
| PBX |
| Extension |
| |||
|
|
|
|
|
|
|
|
|
|
Telephone cord connecting the PBX and a single line telephone (SLT):
CAUSE
The T/R pins are connected to the H/L pins.
H |
|
|
T |
| T |
R |
| R |
L |
|
|
|
|
|
PBX | Extension |
SOLUTION
Use the correct cord (the inner 2 wires are for T/R).
Yes
Can you dial out using an outside (CO) line?
Telephone cord connecting the PBX and an SLT that is
|
| CAUSE | SOLUTION | |||
The T and R pins are crossed over. | Reverse the connections of | |||||
|
|
|
|
|
| the T/R pins. |
| H |
|
|
|
|
|
| T |
|
| T |
|
|
| R |
|
| R |
|
|
| L |
|
|
|
|
|
|
|
|
|
|
|
|
| PBX |
| Extension |
|
Telephone cord connecting an outside (CO) line and the PBX:
|
|
|
| CAUSE | SOLUTION | |||
|
|
|
|
|
|
|
|
|
|
|
| The outside (CO) line(s) is | Reconnect the outside | ||||
|
|
| connected to the H/L pins. | (CO) line(s) to the T/R pins | ||||
| No |
|
|
|
|
| of the telephone jack using | |
|
|
|
|
|
| |||
|
|
|
|
|
| |||
|
|
|
|
|
| |||
|
|
|
|
|
| T |
|
|
|
|
|
|
|
| R |
|
|
|
|
|
|
|
|
|
|
|
|
|
| Outside (CO) line PBX |
| ||||
|
|
|
|
|
|
|
|
|
Installation Manual
83