Panasonic KX-TES824 installation manual Installing KX-TE82480 to KX-TEM824

Page 45

2.3 Installing Optional Service Cards

Installing KX-TE82480 to KX-TEM824

1.Loosen the screws and open the top and bottom front covers. (2.2.3 Opening/Closing Covers)

2.Using cutting pliers, cut the 6 parts marked with circles, and remove the front panel as shown below.

Lower front panel

3.Cut off any excess plastic in order to make the surface smooth.

Installation Manual

45

Image 45
Contents Advanced Hybrid System Installation ManualSystem Components Compatible Proprietary Telephones Abbreviations in this manualImportant Safety Instructions For users in New Zealand only PrecautionsFor users in Australia only For users in Taiwan onlyFor users in Finland, Norway and Sweden only For Future ReferenceHttp//doc.panasonic.de Introduction For Your SAFETY, Please Read the Following Text Carefully Precautions for Users in the United KingdomInstallation Manual Table of Contents Guide for KX-TE Maintenance Console Section System Outline System Highlights System HighlightsMain Unit Basic System ConstructionOutside CO Line System Connection DiagramGeneral Description SpecificationsCharacteristics System Capacity System CapacityMaximum Cards and Terminal Equipment System DataMax. Quantity Section Installation Before Installing Before InstallingSafety Installation Instructions Installation PrecautionsBefore Installing Unpacking Installing the Advanced Hybrid SystemNames and Locations Opening Covers Opening/Closing CoversClosing Covers Securing Cords To remove the rivet, use a screwdriver as shown below Connect the frame of the PBX to earth Connecting Frame EarthConnecting Backup Batteries Battery Rating 24 Ah Mounting on a Wooden Wall Wall MountingMounting on a Concrete or Mortar Wall Installing the Advanced Hybrid System Installing Surge Protector InstallationOverview Installation of an Earth Rod Outside InstallationInstalling the Advanced Hybrid System Location of Optional Service Cards Installing Optional Service CardsFunction Installing KX-TE82483 to KX-TES824Installing Optional Service Cards Installing KX-TE82480 to KX-TES824 Installing Optional Service Cards Installing Optional Service Cards Installing KX-TE82480 to KX-TEM824 Installing Optional Service Cards 4 8-Port SLT Extension Card KX-TE82474 Installing KX-TE82474 to KX-TES824Installing Optional Service Cards Installing KX-TE82474 to KX-TEM824 5 3-Port Caller ID Card KX-TE82493 6 4-Port Doorphone Card KX-TE82461 Message Expansion Card for DISA/UCD OGMs KX- TE82491 8 2-Channel Voice Message Card KX-TE82492 Connecting Outside CO Lines Connecting Outside CO LinesConnection Connecting Extensions Connecting ExtensionsMaximum Cabling Distance of Extension Wiring Twisted Cable Telephone Wiring Connecting Extensions in Parallel Connecting Doorphones and Door Openers Connecting Doorphones and Door OpenersInstalling the Doorphone KX-T30865 Maximum Cabling DistanceConnecting Doorphones and Door Openers Connecting Doorphones KX-T30865 Connecting Door Openers Connecting Doorbell or Door Chime Connecting Doorbell or Door ChimeConnecting Peripherals Connecting PeripheralsPC/Printer via RS-232C PagerCircuit Type Signal Name Function For connecting a PC/printer with a 9-pin RS-232C connectorFor connecting a PC/printer with a 25-pin RS-232C connector PC via USB 1.1 interface Power Failure Connections Power Failure ConnectionsStarting the Advanced Hybrid System Starting the Advanced Hybrid SystemStarting the Advanced Hybrid System Starting the Advanced Hybrid System Section Guide for KX-TE Maintenance Console Installing KX-TE Maintenance Console on a PC Installing KX-TE Maintenance ConsoleSetting the Password and Password Security System RequirementsClick Maintenance Console Installing KX-TE Maintenance ConsoleConnection Installing the USB DriverConnection Serial Interface ConnectionWindows 98SE Windows MeWindows Click Continue Anyway Windows XPStarting KX-TE Maintenance Console for the first time → KX-TE Maintenance Console Accessing PBX via Internal ModemSelect Auto Tone or Auto Pulse for Dial Type Click InitialiseConnection Connection Section Troubleshooting Installation TroubleshootingCause Operation System Restart System Reset with System Data Clear Index Numerics Template for Wall Mounting Copyright
Related manuals
Manual 167 pages 36.9 Kb