3. Configuration Using the Web Interface
Configuring ReachDSL Ports (8955)
Use the Configuration - DSL Port screen to set parameters for a DSL port on the 8955 ReachDSL line card.
Procedure
To configure a ReachDSL port:
1.Select a Port from the
2.Enter or select the following fields:
Field | Description |
|
|
Line Circuit Name | Enter a name from 1 to 255 characters long to indicate to |
| whom the port is assigned. The following values are |
| reserved and cannot be used: AVAILABLE (port is not |
| assigned), and FAULTY (port is faulty and can not be |
| assigned). |
|
|
Line Code | The Line Code parameter currently has no effect on a |
| ReachDSL card. |
|
|
DSL Line Profile Name | Enter the name of a DSL line profile to set rates for the |
| port. |
|
|
DSL Alarm Profile Name | Enter the name of a DSL alarm profile to set alarm |
| thresholds for the port. |
|
|
Equivalent Working Length | Specify the estimated length of the DSL line. This used to |
| limit transmit rates and maximum transmit power settings |
| according to local spectrum management guidelines. |
|
|
Max Tx Power | Specify the maximum transmit power setting for the |
| |
| may be limited according to local spectrum management |
| guidlines. The actual transmit power level will be based |
| upon the symbol rate selected to maximize the transmit |
| data rate and may be lower than the Maximum Transmit |
| Power level configured. |
|
|
Far End Max Tx Power | Specify the maximum transmit power setting for the |
| |
| may be limited according to local spectrum management |
| guidlines. The actual transmit power level will be based |
| upon the symbol rate selected to maximize the transmit |
| data rate and may be lower than the Maximum Transmit |
| Power level configured. |
|
|
Port Status | Select Enabled, Disabled, or Reset from the |
| list to determine the status of the port. |
|
|
3. Click on Apply.
June 2004 |