3. Configuration Using the Web Interface
3. Click on Apply.
Creating Line Profiles for Ports (8985)
Procedure
To create a line profile for SHDSL ports:
1.Click on Create New Profile. The SHDSL Profile Create screen appears.
2.Enter or select the following fields:
Field | Description |
|
|
Profile Name | Specify a name for this line profile. |
|
|
Max Rate | Enter a maximum rate from 192 to 2304 kbps. |
|
|
Min Rate | Enter a minimum rate from 192 to 2304 kbps. |
|
|
Mode | Select the regional setting supported, as specified by |
| |
| Annex A |
| Annex B |
| Both |
|
|
Remote Management | Select Enable or Disable from the |
| determine whether remote management is supported for |
| the network element this profile is assigned to. |
|
|
Reference Clock | Select the timing source from the |
| System – Clocking is provided by the backplane. (The |
| backplane clock is configured on the Configuration - |
| System - Clocking screen.) |
| Local – Clocking is provided by an onboard oscillator. |
|
|
Target Margin | Enter a target noise margin from |
|
|
Interface | Select an interface from the |
| Wire Pair 1 – The profile applies to Wire Pair 1. |
| Wire Pair 2 – The profile applies to Wire Pair 2. |
| Select Wire Pair 1 if this profile is to be used for ports that |
| use only one wire pair. |
|
|
3. Click on Apply.
June 2004 |