Haier AD182AMEAA, AD482AMEAA, AD362AMERA, AD362AMEAA, AD282AMERA Trouble Shooting, Remarks

Page 20

19

 

 

 

For remote

 

Failure code

 

For central

 

Failure description

 

Reason

 

Remarks

Error

 

 

 

 

 

 

 

 

 

 

 

type, flash

 

on wired

 

control,

 

 

 

 

 

 

 

 

 

 

times

 

controller

 

failure code

 

 

 

 

 

 

 

display

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

01(01H)

 

01D

 

Indoor ambient temp. sensor failure

 

Sensor broken down or short circuit for more than 2m continuously

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

02(02H)

 

02D

 

Indoor coil temp. sensor failure

 

Sensor broken down or short circuit for more than 2m continuously

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

 

74(4AH)

 

11D

 

Outdoor ambient temp. sensor failure

 

Sensor broken down or short circuit for more than 2m continuously

 

 

 

(

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

 

73(49H)

 

12D

 

Outdoor coil temp. sensor failure/Compressor

 

Sensor broken down or short circuit for more than 2m continuously

 

 

 

For

 

 

 

 

 

 

 

 

 

discharging temp. sensor abnormal

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

 

72(48H)

 

10D

 

Over-current protection / Power supply

 

CT check abnormal 3 times in 30m / Fault phase, short of phase,

 

 

 

*EAA

 

 

 

 

 

 

 

 

 

abnormal

 

out of balance greatly

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

 

83(53H)

 

14D

 

High/Low pressure abnormal

 

High pressure switch acts 3 times in 30m/Low pressure switch acts

 

 

 

 

 

 

 

 

 

 

 

 

 

 

in normal running

 

 

 

series

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

 

07(07H)

 

06D

 

Communication between wired

 

Communication abnormal for more than 4m continuously

 

 

 

 

 

 

 

 

 

 

 

 

controller and indoor abnormal

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

)

9

 

06(06H)

 

05D

 

Communication between indoor and outdoor abnormal

 

Communication abnormal for more than 4m continuously

 

 

 

 

 

10

 

08(08H)

 

21D

 

Drainage system abnormal

 

Float switch broken down for more than 25m continuously

 

 

 

 

 

11

 

11(0BH)

 

30D

 

Outside alarm signal input

 

Outside signal broken down for more than 10s

 

 

 

 

 

12

 

03(03H)

 

20D

 

Gas pipe temp. sensor abnormal

 

Sensor broken down or short circuit for more than 2m continuously

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

13

 

13(0DH)

 

31D

 

Temperature protection malfunction

 

Solenoid valve act incorrectly 3 times continuously

 

 

 

 

 

15

 

05(05H)

 

17D

 

EEPROM abnormal

 

EEPROM data missing

 

 

 

 

17

 

80(50H)

 

15D

 

Compressor overheat

 

The discharging temperature is higher than 120degree

 

Resumable if

 

 

 

 

 

 

 

lower than

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100 degree

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

18

 

12(0CH)

 

23D

 

Abnormal mode

 

Indoor operation mode is different with the running indoor unit.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

19

 

75(4BH)

 

18D

 

Outdoor coil B(suction temp sensor-for MRV II)

 

Sensor broken down or short circuit for more than 2m continuously

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20

 

77(4DH)

 

15D

 

Outdoor discharging B(oil temp sensor-for MRV II)

 

Sensor broken down or short circuit for more than 2m continuously

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

shows resumable fault, shows it is not resumable fault.

Trouble Shooting

Image 20
Contents Duct Type AIR Conditioner Please keep this manual carefully and safelyTable of Contents Disposal of the old air conditioner Safety Precautions Circuit breaker may be necessary Positive drainingNeither stand on the air conditioner nor Machine is adaptive in following situation OutdoorParts and Functions Duct Air outlet Air inletMalfunction Unit fails to startCooling or heating is not sufficient Cooling is not sufficientCase of Auto mode, operation mode is changed automati Followings are not malfunctionWater flowing sound is heard This is caused by heat expansion or contraction of plasticsCare and Maintenance Points to observeFor Preparation of HeatingHot Keep Is The Unit Installed Correctly Installation placeWhen you change your address or the installation place For inspection and maintenanceInstallation Manual For Indoor Unit Serious injury are listedCombination 416mmPreparation of indoor unit Avoid installation and use at those places listed below Hanger bolts installationInstallation of indoor unit Adjusting to the levelnessTap selection on blower unit Drain PipingProcedures Drainage TestConnection of suction, exhaust ducts Installation work for air outlet ductsBlowout duct Wiring connection ModelRemarks Trouble ShootingShows resumable fault, shows it is not resumable fault Resumable if DegreeHaier Group