For Preparation of Heating("Hot Keep")

"HOT KEEP"is operated in the following cases.

When heating is started:

In order to prevent blowing out of cool wind, the indoor unit fan stopped according to the room temperature which heating operation is started. Wait for approx. 2 to 3 minute, and the operation will be automatically changed to the ordinary heating mode.

Defrosting operation (in the heating mode):

When it is liable to frost. the heating operation is stopped automatically for 5 to 12 minutes once per approx. one hour, and defrosting is operated. After defrosting is completed, operation mode is automatically changed to ordinary heating operation.

When the room thermostat is actuated:

When room temperature increases and room temperature controller actu- ates, the fan speed is automatically changed to stop under low temperature condition of indoor heat exchanger. When room temperature decreases, air conditioner automatically changes over to ordinary heating operation.

WARMING OPERATION

Heat pump type warming

With the heat pump type warming, the mechanism of heat pump that concentrate heat of outdoor air with the help of refrigerant to warm the indoor space, is utilized.

Defrosting operation

When a room is warmed with a heat pump type air conditioner, frost accumulates on the heat ex- changer of outdoor unit along with the drop of indoor temperature. Since the accumulated frost re- duces the effect of warming, it is necessery to automatically switch the operation to the defrosting mode. During the defrosting operation, heating operation is interrupted.

Atmospheric temperature and warming capacity

Warming capacity of heat pump type air conditioner decreases along with the drop of outdoor temperature.

When the warming capacity is not sufficient, it is recommended to use another heating implement.

Period of warm-up

Since the heat pump type air conditioner employs a method to circulate warm winds to warm the entire space of a room, it takes time before the room tem- perature rises.

It is recommendable to start the operation a little earlier in a very cold morning.

10

Image 11
Contents Please keep this manual carefully and safely Duct Type AIR ConditionerTable of Contents Disposal of the old air conditioner Circuit breaker may be necessary Positive draining Safety PrecautionsNeither stand on the air conditioner nor Outdoor Machine is adaptive in following situationDuct Air outlet Air inlet Parts and FunctionsCooling is not sufficient MalfunctionUnit fails to start Cooling or heating is not sufficientThis is caused by heat expansion or contraction of plastics Case of Auto mode, operation mode is changed automatiFollowings are not malfunction Water flowing sound is heardPoints to observe Care and MaintenanceFor Preparation of HeatingHot Keep For inspection and maintenance Is The Unit Installed CorrectlyInstallation place When you change your address or the installation placeSerious injury are listed Installation Manual For Indoor UnitCombination 416mmPreparation of indoor unit Hanger bolts installation Avoid installation and use at those places listed belowDrain Piping Installation of indoor unitAdjusting to the levelness Tap selection on blower unitDrainage Test ProceduresConnection of suction, exhaust ducts Installation work for air outlet ductsBlowout duct Model Wiring connectionRemarks Trouble ShootingShows resumable fault, shows it is not resumable fault Degree Resumable ifHaier Group