Haier AD362AMERA, AD482AMEAA Followings are not malfunction, Water flowing sound is heard

Page 9

Malfunction

The followings are not malfunction

Water flowing sound is heard.

Shuru Shuru

When the air conditioner is started, when the compressor starts or stops during operation or when the air conditioner is stopped, it sometimes sounds "shuru shuru" or "gobo gobo". It is the flowing sound of the refrigerant, and it is not a trouble.

Cracking sound is heard.

This is caused by heat expansion or contraction of plastics.

 

It smells.

Air which blows out from the indoor unit sometimes smells.

 

 

The smell results from residents of tobacco smoke or cosmetics

 

stuck inside of unit.

 

During operation,

When the air conditioner is used at restaurant etc. where dense

white fog comes

edible oil fume is always exists, white fog sometimes blows out

out of indoor unit.

of air outlet during operation.

 

 

In this case consult sales dealer for cleaning the heat exchanger.

It is switched into the FAN mode

To prevent frost from being accumulated on the indoor unit heat

during cooling.

exchanger, it is sometimes automatically switched to the FAN mode

 

but it will soon return to the cooling mode.

 

The air conditioner can not be

Even if the operation switch is turned on, cooling, dehumidifying

restarted soon after it stops.

or heating is not operable for three minutes after the conditioner is

Unit does

stopped. Because the protecting circuit is activated.

Wait for

(During this time air conditioner operates in fan

three

not start

minutes

 

mode.)

 

Air does not blow or the fan

When it is excessively cooled during dehumidifying, the blower

speed can not be changed during

automatically repeats reducing and lowering the fan speed.

 

dehumidifying

 

 

During operation, operation mode

Isn't the AUTO mode selected?

 

has changed over automatically.

In the case of AUTO mode, operation mode is changed automati-

 

cally from cooling to heating or vise-versa according to the room

 

temperature.

 

Water or steam generates from

This results when frost accumulated on the outdoor unit is removed

the outdoor unit during heating.

(during defrosting operation).

 

8

Image 9
Contents Please keep this manual carefully and safely Duct Type AIR ConditionerTable of Contents Disposal of the old air conditioner Circuit breaker may be necessary Positive draining Safety PrecautionsNeither stand on the air conditioner nor Outdoor Machine is adaptive in following situationDuct Air outlet Air inlet Parts and FunctionsUnit fails to start MalfunctionCooling or heating is not sufficient Cooling is not sufficientFollowings are not malfunction Case of Auto mode, operation mode is changed automatiWater flowing sound is heard This is caused by heat expansion or contraction of plasticsPoints to observe Care and MaintenanceFor Preparation of HeatingHot Keep Installation place Is The Unit Installed CorrectlyWhen you change your address or the installation place For inspection and maintenanceSerious injury are listed Installation Manual For Indoor Unit416mm Preparation of indoor unitCombination Hanger bolts installation Avoid installation and use at those places listed belowAdjusting to the levelness Installation of indoor unitTap selection on blower unit Drain PipingDrainage Test ProceduresInstallation work for air outlet ducts Blowout ductConnection of suction, exhaust ducts Model Wiring connectionTrouble Shooting Shows resumable fault, shows it is not resumable faultRemarks Degree Resumable ifHaier Group