Haier AD142AMBIA, AU142AFBIA Outline piping, Piping size, Precautions for refrigerant piping

Page 14

INSTALLATION MANUALFOR OUTDOOR UNIT

4.Refrigerant piping

(1)Outline piping

Flare connection

Indoor unit

(2) Piping size

Liquid pipe

9.52x0.8mm

Gas pipe

15.88x1.0mm

Liquid

3-way valve

pipe

 

 

Outdoor

 

unit

Gas pipe

3-way valve

 

 

Flare connection

Install the removed flared nuts to the pipes to be connected, then flare the pipes.

90 + 0.5

(3)Limitations for one way piping length and vertical height difference. One way piping length: less than 15m.

Vertical height difference: Less than 5m.

Precautions for refrigerant piping

Do not twist or crush piping.

Be sure that no dust is mixed in piping.

Bend piping with as wide angle as possible.

Keep insulating both gas and liquid piping.

Check flare-connected area for gas leakage.

(4) Piping connection

Connecting method

Apply refrigerant oil at half union and flare nut.

To bend a pipe, give the roundness as large as possible not to crash the pipe.

When connecting pipe, hold the pipe centre to centre then screw nut on by hand, refer to Fig. Be careful not to let foreign matters, such as sands enter the pipe.

Forced fastening without centering may damage the threads and cause a gas leakage.

Pipe dia

Fastening torque

 

 

Liquid pipe 9.52mm(3/8")

42N.m

Gas pipe 15.88mm(5/8")

60N.m

13

Image 14
Contents Operation & Installation Manual Table of Contents Disposal of the old air conditioner Safety Precautions Make sure the system is groundedDo not wash the air conditioner with water Applicable ambient temperature range Machine is adaptive in following situationParts and Functions Cooling or heating is not sufficient MalfunctionUnit fails to start Cooling is not sufficientFollowings are not malfunction Points to observe Care and MaintenanceCleaning When the room thermostat is actuated When heating is startedDefrosting operation in the heating mode Atmospheric temperature and warming capacityInstallation Manual for Outdoor Unit Installation placeOpen space requirement around the unit Installation where the area with strong windsInstallation Piping size Precautions for refrigerant pipingOutline piping Piping connectionInstallation Manual for Outdoor Unit Installation Manual for Indoor Unit Avoid installation and use at those places listed below Preparation of indoor unit225 Preparation for suspending the unitNew cement panel Install the hoisting screwWood structure Suspending of indoor unit Original cement panelSteel structure RequirementsPermitted length and fall of connection pipe Material of connection pipe and thermal insulationConfirm drainage Connection of refrigerant pipeInstallation Manual for Electric Wiring Electric wiringWire. And the two ends of the shield Pay attention not to damage PC boardCheck and Test RUN Configuration of power supplyInstallation check and test run Set of the air sending of the fan motor