Haier AU142AFBIA, AD142AMBIA Install the hoisting screw, Wood structure, New cement panel

Page 19

INSTALLATION MANUAL FOR INDOOR UNIT

M8 wide expansion screw bolt

M8 hoisting screw

M8 wide lock washer

M8 screw nut

A amplified

(Figure 5)

Unit

28

B

Air supply passage

C

(Figure 6)

 

 

 

 

B amplified

B

B Rivet

 

 

 

 

 

 

 

 

 

 

Use screw to

 

 

 

 

 

 

 

 

 

fix top panel

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C amplified

 

Top panel of unit

Air supply

 

passage

Air outlet grille

 

Install the hoisting screw

Use M8 or M10 hoisting screw (4, prepare on site) (When the height of hoisting screw is more than 0.9m, you must use M10), their gaps refer to the dimension of air conditioner, according to the original structure and the following method to install.

Wood structure

Put up the frame wood on the beam and mount the hoisting screws.

Frame wood

Hoisting screw

Beam

New cement panel

Use embedded parts and foot screw, etc to mount.

 

Iron

 

Foot screw

(Knife type

(Louver type embedded part)

(hoisting foot screw for

embedded part)

connection pipe)

 

18

Image 19
Contents Operation & Installation Manual Table of Contents Disposal of the old air conditioner Make sure the system is grounded Safety PrecautionsDo not wash the air conditioner with water Machine is adaptive in following situation Applicable ambient temperature rangeParts and Functions Cooling is not sufficient MalfunctionUnit fails to start Cooling or heating is not sufficientFollowings are not malfunction Cleaning Care and MaintenancePoints to observe Atmospheric temperature and warming capacity When heating is startedDefrosting operation in the heating mode When the room thermostat is actuatedInstallation place Installation Manual for Outdoor UnitInstallation Installation where the area with strong windsOpen space requirement around the unit Piping connection Precautions for refrigerant pipingOutline piping Piping sizeInstallation Manual for Outdoor Unit Installation Manual for Indoor Unit Preparation of indoor unit Avoid installation and use at those places listed belowPreparation for suspending the unit 225Wood structure Install the hoisting screwNew cement panel Requirements Original cement panelSteel structure Suspending of indoor unitConnection of refrigerant pipe Material of connection pipe and thermal insulationConfirm drainage Permitted length and fall of connection pipeElectric wiring Installation Manual for Electric WiringPay attention not to damage PC board Wire. And the two ends of the shieldSet of the air sending of the fan motor Configuration of power supplyInstallation check and test run Check and Test RUN