Haier AU142AFBIA Pay attention not to damage PC board, Wire. And the two ends of the shield

Page 23

INSTALLATION MANUAL FOR WIRE CONTROLLER

1.Remove the upper cover of wire controller

Upper cover of

wire controller

The PC board is installed on the back cover of

 

 

wire controller. When remove the upper cover,

FC

SET RECOVERY

 

HEALTH

 

pay attention not to damage PC board.

CHECK

 

 

Back cover of

 

wire controller

2.Install wire controller

**Drill 2 wall holes according to the position of the 2 screw holes on the back *cover of wire controller, then hit wood in the wall holes. Put the 2 screw holes *on the back cover of wire controller properly to its corresponding wood, then *use wood screws to fix the back cover on the wall.

Note:

Install the back cover of wire controller on the even wall as possible as can. When tightening the wood screw, do not use to tight force, otherwise the wire controller may be damaged.

Note:

When connecting wire, please keep a certain distance between signal wire and electric wire. (over 10mm)

Dimension of signal wire:

Type of wire Shield wire (4 cords)

Dimension 0.33mm2

3.Indoor unit wire connection

Connect the terminals (A, B, C, D,) on the wire The connection between indoor unit

controller to the terminals on the indoor PC

and wire controller and indoor unit

and outdoor unit should use shield

panel (A, B, C, D,) respectively.

 

 

 

 

wire. And the two ends of the shield

 

 

 

 

 

Arrange wire from this part

 

 

 

wire

should

be grounded,

AB

CD

 

 

 

otherwise, the disturbance will

 

Back cover

 

 

 

cause unit abnormal operation.

HEALTH

 

HEALTH

 

 

 

 

FC

SET RECOVERYwire controller

FC

SET RECOVERY

Upper cover

Shield wire

CHECK

 

 

CHECK

of wire

 

 

 

 

 

controller

Grounded

Grounded

Note:

Confirm the connection part of terminals is firm and will not touch shield wire.

4.Cover the wire controller upper cover

Pay attention not to press the connection wire.

Note: Do not touch PC board by hand.

22

Image 23
Contents Operation & Installation Manual Table of Contents Disposal of the old air conditioner Make sure the system is grounded Safety PrecautionsDo not wash the air conditioner with water Machine is adaptive in following situation Applicable ambient temperature rangeParts and Functions Cooling is not sufficient MalfunctionUnit fails to start Cooling or heating is not sufficientFollowings are not malfunction Points to observe Care and MaintenanceCleaning Atmospheric temperature and warming capacity When heating is startedDefrosting operation in the heating mode When the room thermostat is actuatedInstallation place Installation Manual for Outdoor UnitOpen space requirement around the unit Installation where the area with strong windsInstallation Piping connection Precautions for refrigerant pipingOutline piping Piping sizeInstallation Manual for Outdoor Unit Installation Manual for Indoor Unit Preparation of indoor unit Avoid installation and use at those places listed belowPreparation for suspending the unit 225New cement panel Install the hoisting screwWood structure Requirements Original cement panelSteel structure Suspending of indoor unitConnection of refrigerant pipe Material of connection pipe and thermal insulationConfirm drainage Permitted length and fall of connection pipeElectric wiring Installation Manual for Electric WiringPay attention not to damage PC board Wire. And the two ends of the shieldSet of the air sending of the fan motor Configuration of power supplyInstallation check and test run Check and Test RUN