TROUBLESHOOTING

Message

Cause

Action

Weak GPS signal

Not applicable for Automower® 320.

If the message appears often, turn off the GPS

 

The GPS signal is weak for the current

assisted navigation and instead use the manual

 

working area. GPS assisted navigation

settings for Lawn coverage. See 6.8 Installation on

 

cannot be used.

page 49.

Guide calibration failed

The robotic lawn mower has failed to

Check that the guide wires are installed according

 

calibrate the guide wire.

to the instructions, See 3.6 Installation of the guide

 

 

wire on page 28

9.3 Indicator lamp in the charging station

For a fully functional installation, the indicator lamp in the charging station must emit a solid green light. If something else appears, follow the troubleshooting guide below.

There is more troubleshooting help on www.automower.com. If you still need help with troubleshooting, please contact the local dealer.

Light

Cause

Action

 

 

 

Solid green light

Good signals

No action required

 

 

 

Green flashing light

The signals are good and ECO mode

No action required. For more information on ECO

 

is activated.

mode, see 6.9 Settings on page 59.

 

 

 

Blue flashing light

The boundary loop is not connected

Check that the boundary wire connectors are

 

to the charging station

fitted properly to the charging station. See 3.5

 

 

Connecting the boundary wire on page 27.

 

Break in the boundary loop

Find out where the break is. Replace the

 

 

damaged section of the loop with a new loop

 

 

wire and splice using an original coupler.

 

 

 

Red flashing light

Interruption in the charging station’s

Contact the local dealer.

 

antenna

 

 

 

 

Solid blue light

Weak signal as the boundary wire is

No steps have to be taken if the robotic

 

too long. Max length is 800 metres.

lawnmower operates as expected.

 

 

 

 

 

Shorten the boundary wire by reducing the

 

 

working area or replacing islands with barriers

 

 

therobotic lawnmower can collide with.

 

 

 

 

Weak signal due to damaged

Since it is difficult to locate where the wire

 

boundary wire

is damaged it is recommended to lay a new

 

 

boundary wire for the entire working area.

 

 

 

Solid red light

Defective circuit board in the

Contact the local dealer.

 

charging station

 

 

 

 

English - 79

Page 81
Image 81
Husqvarna 320, 330X manual Indicator lamp in the charging station, Light Cause Action