Connecting the transformer

Take the following into consideration when planning
where to place the transformer:
Close to the charging station
Protection from rain
Protection from direct sunlight
If the transformer is connected to an electrical socket
outdoors, this must be approved for outdoor use.
The low voltage cable for the transformer is 10 metres
long, and may not be shortened or extended. A longer low
voltage cable is available as optional accessory. Please
contact your dealer for more information.
It is not allowed to connect the transformer directly to the
charging station. The low voltage cable must always be
used.
IMPORTANT INFORMATION
The low voltage cable must not under any
circumstances be shortened or extended.
It is possible to let the low voltage cable cross the working
area. The low voltage cable must be stapled down or
buried, and the cutting height should be such that the
blades on the blade disc can never come in contact with
the low voltage cable.
Make sure the low voltage cable is laid along the ground
and secured with pegs 75 cm apart. The cable must lie
close to the ground so as not to be cut before the grass
roots have grown over it.
IMPORTANT INFORMATION
Place the low voltage cable so that the
blades on the blade disc can never come
in contact with it.
The transformer must be placed where it is well ventilated
and is not exposed to direct sunlight. The transformer
must be placed under a roof.
It is recommended to use an earth fault-breaker when
connecting the transformer to the wall socket.
The transformer must be mounted on a vertical surface,
such as a wall or a fence. Screw the transformer in place
using the two mounting eyelets. No screws are supplied.
Select screws suitable for the material in question.
min 30cm/12”
3018-094
3012-1214
3018-069
3018-085