INSTALLATION
3.5 Connecting the boundary wire
Connect the boundary wire to the charging station:
IMPORTANT INFORMATION
The boundary wire must not be crossed when connecting it to the charging station. The right hand wire end must be connect- ed to the right hand pin on the charging station and the left hand wire end to the left pin.
1.Place the wire ends in the connector: • Open the connector.
• Place the wire in the connector grip.
2.Press the connectors together using a pair of pliers. Press until you hear a click.
3.Cut off any surplus boundary wire. Cut
4.Tilt the protective cover on the charging station forward and run the wire ends up each channel at the rear of the charging station. Press the connector onto the metal pins, marked AL (left) and AR (right), on the charging station.
5.Mark the wires with the accompanying wire labels. This makes it easier to reconnect the wires correctly when for instance the charging station has been stored indoors for the winter.
IMPORTANT INFORMATION
The right hand connector must be con- nected to the right hand metal pin on the charging station and the left hand wire end to the left connector.
English - 27