INSTALLATION
Do not, under any circumstances, mount the transformer at a height where there is a risk it can be submerged in water (at least 30 cm from the ground). It is not permitted to place the transformer on the ground.
IMPORTANT INFORMATION
Use the transformer’s plug to disconnect the charging station, for instance before cleaning or repairing the loop wire.
Installing and connecting the charging station
1. Position the charging station in a suitable spot.
2. Tilt the protective cover on the charging station forward and connect the low voltage cable to the charging station.
3.Connect the transformer’s power cable to a 110- 230 V wall socket.
4. Attach the charging station to the ground using the supplied screws. Ensure the screws are screwed all the way down in the countersink. If the charging station is placed against a wall, it is best to wait before securing the charging station to the ground until after all the wires have been connected.
IMPORTANT INFORMATION
It is not permitted to make new holes in the charging station’s plate. Only the existing holes may be used to secure the base plate to the ground.
IMPORTANT INFORMATION
Do not tread or walk on the charging station’s plate.
English - 19