Installation Procedures

HOW TO CONNECT WIRING TO THE TERMINALS

A.For solid core wiring (or F-cable)(Fig.24A)

(1)Cut the wire with a wire cutter or wire-cutting pliers, then strip the insulation to about 25mm of the exposed solid wire.

(2)Using a screwdriver, remove the terminal screw(s) on the terminal board.

(3)Using pliers, bend the solid wire to form a loop suitable for the terminal screw.

(4)Shape the loop wire properly, place it on the terminal board and tighten securely with the terminal screw using a screw driver.

B.For strand wiring(Fig.24B)

(1)Cut the wire with a wire cutter or wire-cutting pliers, then strip the insulation to about 10mm of the exposed strand wiring.

(2)Using a screwdriver, remove the terminal screw(s)on the terminal board.

(3)Using a round terminal fastener or pliers, securely clamp a round terminal to each stripped wire end.

(4)Position the round terminal wire, and replace and tighten the terminal screw using a screw driver.

Fig. 24

25mmStrip

A. Solid wire

 

Loop

 

 

Insulation

B. Strand wire

Strip 10mm

Round terminal

Wire

Screw with special washer

Round

terminal

Terminal

board

Wire

Screw with special washer

Round terminal

HOW TO FIXED CONNECTION CORD AND POWER CABLE AT THE CORD CLAMP

After passing the connection cord and power cable through the insulation tube, fasten it with the cord clamp, as shown in Fig.25

Fig. 25

Insulation tube

Cord clamp

Use VW-1, 0.5 to 1.0 mm thick, PVC tube as the insulation tube.

13

Image 15
Contents Operation & Installation Manual Contents Disposal of the old air conditioner DB C WB C Maximum Minimum IndoorDB C WB CSafety Precautions Indoor Unit Name of PartsCleaning the Air Filter Cleaning and CareOperation Tips Drain hosePiping hole cover Location InstallationSelecting the Mounting Position Installation ProceduresWall 6mm Rear 7cm Right Indoor unit Preparing Indoor Unit InstallationFloor Console Type Drilling for PipingDrain pan Drain hose Insulation Drain hose Installing Drain HoseUnder Ceiling Type Drain pan Nylon fastener Drain hoseWith a concrete drill, drill four 12.7 mm dia. Holes Installing BracketsSelect piping and drain directions WallConnecting the Piping Install the Drain HoseFlare Processing Round terminal InsulationElectrical Wiring Indoor Unit SideElectrical Requirement Customer Guidance Electrical WiringMount the Cover Plate Intake Grill Check ItemsMount the intake grill Followings are not problems Trouble ShootingPoor cooling or heating Error display For *.ERA Error display For *.EAA Haier Group