Haier AC182ACEAA, AC142ACERA, AC142ACEAA, AC242ACEAA Operation Tips, Drain hose, Piping hole cover

Page 8

Operation Tips

Operation and Performance

*Heating Performance

This air conditioner operates on the heat-pump principle, absorbing heat from outdoor air and transferring that heat indoors. As a result, the operating performance is reduced as outdoor air temperature drops. If you feel that insufficient heating perfomance is being produced, we recommend you use this air conditioner in conjunction with another kind of heating appliance.

Heat-pump air conditioners heat your entire room by recirculating air throughout the room, with the result that some time may be required after first starting the air conditioner until the room is heated.

Instructions relating to heating (*) are applicable only to "HEAT & COOL TYPE".

*Microcomputer-controlled Automatic Defrosting

When using the Heating mode under conditions of low outdoor air temperature high humidity, frost may form on the outdoor unit, resulting in reduced operating performance.

In order to prevent this kind of reduced performance, this unit is equipped with a Microcomputer-controlled Automatic Defrosting function. If frost forms, the air conditioner will temporarily stop, and the defrosting circuit will operate briefly (for about 7 to 15 minutes).

STANDARD PARTS

The following installation parts are furnished. Use

them as required.

Optional parts

Mark

Parts name

A

Adhesive tape

BSaddle (L.S) with screws

C

Drain hose

DHeat insulation material

E

Piping hole cover

F

Putty

G

Plastic clamp

6

Image 8
Contents Operation & Installation Manual Contents Disposal of the old air conditioner Maximum Minimum Indoor DB CWB C DB C WB CSafety Precautions Name of Parts Indoor UnitCleaning and Care Cleaning the Air FilterPiping hole cover Operation TipsDrain hose Installation LocationInstallation Procedures Selecting the Mounting PositionPreparing Indoor Unit Installation Floor Console TypeDrilling for Piping Wall 6mm Rear 7cm Right Indoor unitInstalling Drain Hose Under Ceiling TypeDrain pan Nylon fastener Drain hose Drain pan Drain hose Insulation Drain hoseInstalling Brackets Select piping and drain directionsWall With a concrete drill, drill four 12.7 mm dia. HolesFlare Processing Connecting the PipingInstall the Drain Hose Insulation Round terminalElectrical Requirement Electrical WiringIndoor Unit Side Electrical Wiring Mount the Cover Plate Intake GrillCheck Items Customer GuidanceMount the intake grill Trouble Shooting Followings are not problemsPoor cooling or heating Error display For *.ERA Error display For *.EAA Haier Group