Installation Procedures
2. INSTALLING DRAIN HOSE
Select whether the drain hose will be connected
Wrap the insulation (drain hose) around the drain
to the left or right side.(Fig.3) Insert the drain hose into the drain pan, then secure the drain hose with a nylon fastener. (Fig.6)
(Fig. 6)
Drain pan
Nylon fastener
Drain hose
hose connection. (Fig.7)
(Fig. 7)
Drain pan
Drain hose
Insulation (Drain hose)
Be sure to arrange the drain hose correctly so that it is leveled lower than the drain hose connecting port of the indoor unit.
Fig. 8 | OK | NO | NO |
Arrange the drain hose | Drain hose | |
lower than this portion. | ||
|
CAUTION
Do not install the unit drain hose side is too high. Height A should be less than 5 mm.(Fig.9)
Fig. 9
Drain hose
A A
B. UNDER CEILING TYPE
Using the installation template, drill holes for piping and anchor bolts(for holes).(Fig.10)
900mm
Installation
Drilling position for anchor bolt
200mmtemplate
Ceilling
Fig. 10 | Wall |
Drilling position for piping
10