Haier AC182ACEAA Installing Drain Hose, Under Ceiling Type, Drain pan Nylon fastener Drain hose

Page 12

Installation Procedures

2. INSTALLING DRAIN HOSE

Select whether the drain hose will be connected

Wrap the insulation (drain hose) around the drain

to the left or right side.(Fig.3) Insert the drain hose into the drain pan, then secure the drain hose with a nylon fastener. (Fig.6)

(Fig. 6)

Drain pan

Nylon fastener

Drain hose

hose connection. (Fig.7)

(Fig. 7)

Drain pan

Drain hose

Insulation (Drain hose)

Be sure to arrange the drain hose correctly so that it is leveled lower than the drain hose connecting port of the indoor unit.

Fig. 8

OK

NO

NO

Arrange the drain hose

Drain hose

lower than this portion.

 

CAUTION

Do not install the unit drain hose side is too high. Height A should be less than 5 mm.(Fig.9)

Fig. 9

Drain hose

A A

B. UNDER CEILING TYPE

Using the installation template, drill holes for piping and anchor bolts(for holes).(Fig.10)

900mm

Installation

Drilling position for anchor bolt

200mmtemplate

Ceilling

Fig. 10

Wall

Drilling position for piping

10

Image 12
Contents Operation & Installation Manual Contents Disposal of the old air conditioner Maximum Minimum Indoor DB CWB C DB C WB CSafety Precautions Name of Parts Indoor UnitCleaning and Care Cleaning the Air FilterOperation Tips Drain hosePiping hole cover Installation LocationInstallation Procedures Selecting the Mounting PositionPreparing Indoor Unit Installation Floor Console TypeDrilling for Piping Wall 6mm Rear 7cm Right Indoor unitInstalling Drain Hose Under Ceiling TypeDrain pan Nylon fastener Drain hose Drain pan Drain hose Insulation Drain hoseInstalling Brackets Select piping and drain directionsWall With a concrete drill, drill four 12.7 mm dia. HolesConnecting the Piping Install the Drain HoseFlare Processing Insulation Round terminalElectrical Wiring Indoor Unit SideElectrical Requirement Electrical Wiring Mount the Cover Plate Intake GrillCheck Items Customer GuidanceMount the intake grill Trouble Shooting Followings are not problemsPoor cooling or heating Error display For *.ERA Error display For *.EAA Haier Group