Haier HDU-18HF03, HDU-18CF03 This series changeover switch is set 1. on 2.OFF 3.OFF 4.OFF

Page 15

Operation

Power Failure Compensation (to be applied for a necessary situation)

After the power failure compensation is set, if power failure suddenly occurs while the air conditioner is working, it will resume the previous working state when the power is supplied again.

Setting Method: When the wire controller is on (excluding timer mode and fan mode), press the "Sleeping" button on the remote controller 10 times within 5 seconds, and after the buzzer rings 4 times, the air conditioner will enter the state of power failure compensation.

Cancel Method: Press the "Sleeping" button on the wire controller 10 times within 5 seconds, and after the buzzer rings 2 timer, the power failure compensation mode will be

cancelled.

Notes: When a power failure suddenly occurs during the air conditioner is working after the power failure compensation is set, if the air conditioner will not be used for a long time, please cut off the power supply to prevent its operation from being resumed after the power is supplied again, or press the "Switch On/Off" button after the power comes again.

Change-over switch

Mark

ON

OFF

1

Fixed Frequency

Inverter

2

Have rise and drop

No rise and drop

3

Swing

Not Swing

4

The collection

The collection

 

temperature of

temperature of wire

 

indoor unit

controller.

 

 

 

In this series changeover switch is set: 1. ON 2.OFF 3.OFF 4.OFF

14

Image 15
Contents Duct Type AIR Conditioner Table of Contents Disposal of the old air conditioner Make sure the system is grounded Safety PrecautionsDo not wash the air conditioner with water Heating Indoor Rated Maximum Minimum IndoorCooling OutdoorParts and Functions Parts and Functions Operation Power ON/OFFCool Fan operation Auto RUN, COOL,HEAT and DRY operation 4Confirming your setting 1After unit start, select your desired operation mode2TIMER mode selection 3Timer setting5Time setting for Timer OFF Press Timer button to change Timer mode3Time setting for Timer on Time confirming for Timer onCooling, dehumidifying mode Heating mode This series changeover switch is set 1. on 2.OFF 3.OFF 4.OFF Unit fails to start MalfunctionMalfunction Followings are not malfunction Points to observe Care and MalntenanceFor Preparation of HeatingHot Keep When heating is startedInstallation place Is The Unit Installed CorrectlyInstall wire controller Installation Manual For Wire ControllerIndoor unit wiring Safety precautions Installation Manual For Indoor UnitIndoor unit Installation Manual For Indoor Unit Sketch map of long duct Installation of air sending duct Installation of air return ductThermal insulation of duct Foundation bolt Requirements Pipe and insulation materialHose Allowable pipe length and drop Pipe material and size Supplementary refrigerantConnection of refrigerant pipe Vacuum pumping Open all valvesGas leakage detection Electric wiring Haier Group