Installation of indoor unit duct

1. Installation of air sending duct

This unit uses rounded duct, the diameter of the duct is 180mm.

The rounded duct needs to add a transition duct to connect with the air-sending duct of indoor unit, then connect with respective separator. As Fig. 1 shown, all the fan speed of any of the separatorís air outlet shall be adjusted approximately the same to meet the requirement for the room air conditioner.

Indoor unit

Soft connection

Transition duct

Rounded duct

or static box

Tie-in of air distributary

Air distributary

Fig. 1

Unit: mm

2. Installation of air return duct

Use rivet to connect the air return duct on the air return inlet of the indoor unit, then connect the other end with the air return blind. As Fig. 2 shown.

Air return blind

Air return duct

Indoor unit

rivet

Fig. 2

3 Thermal insulation of duct

Air-sending duct and air return duct shall be thermally insulated. First stick the gluey nail on the duct, then attach the heat preservation cotton with a layer of tinfoil paper and use the gluey nail cap to fix. Finally use the tinfoil adhesive tape to seal the connected part. As Fig. 3 shown.

gluey

heat preservation

gluey

adhesive tape

nail

cotton

tinfoil nail cap

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fig. 3

27

Image 28
Contents Duct Type AIR Conditioner Table of Contents Disposal of the old air conditioner Safety Precautions Make sure the system is groundedDo not wash the air conditioner with water Rated Maximum Minimum Indoor CoolingOutdoor Heating IndoorParts and Functions Power ON/OFF Parts and Functions OperationCool Fan operation Auto RUN, COOL,HEAT and DRY operation 1After unit start, select your desired operation mode 2TIMER mode selection3Timer setting 4Confirming your settingPress Timer button to change Timer mode 3Time setting for Timer onTime confirming for Timer on 5Time setting for Timer OFFCooling, dehumidifying mode Heating mode This series changeover switch is set 1. on 2.OFF 3.OFF 4.OFF Malfunction Unit fails to startMalfunction Followings are not malfunction Care and Malntenance Points to observeWhen heating is started For Preparation of HeatingHot KeepIs The Unit Installed Correctly Installation placeInstallation Manual For Wire Controller Install wire controllerIndoor unit wiring Installation Manual For Indoor Unit Safety precautionsIndoor unit Installation Manual For Indoor Unit Sketch map of long duct Installation of air return duct Installation of air sending ductThermal insulation of duct Foundation bolt Pipe and insulation material RequirementsHose Supplementary refrigerant Allowable pipe length and drop Pipe material and sizeConnection of refrigerant pipe Open all valves Vacuum pumpingGas leakage detection Electric wiring Haier Group