Contents of the menus (continued)

SYSTEM Menu (continued)

 

Items

Setting

 

Contents

INDEX WRITE

OFF

Use this setting to enable/disable index signal recording.

 

 ON

OFF

: No recording of index signal.

 

 

ON

: Use this setting to record index signals. An index signal is

 

 

 

automatically registered at the position where recording

 

 

 

starts.

REMOTE menu

The REMOTE menu consists of 2 menus. (1/2 and 2/2 menu)

REMOTE (1/2) menu

Items

Setting

Contents

REMOTE

OFF

Use this menu item to enable/disable the REMOTE SEL. switch on

 

 ON

the front panel.

 

 

OFF : Disables the 9 PIN/SERIAL setting of the REMOTE SEL.

REPEAT MODE

 OFF

 

INDEX

 

VIDEO OUT

 

TAPE END

Use this setting to enable/disable repeat playback.

OFF

: No repeat playback

INDEX

: Repeat playback between the positions where in-

 

dex signals are recorded.

VIDEO END

: Repeat playback from the beginning of the tape to

 

the position where recording of video signals ends.

TAPE END

: Repeat playback from the beginning to the end of

 

the tape.

 

 

switch.

 

 

ON : Enables the 9 PIN/SERIAL setting of the REMOTE SEL.

 

 

switch. Use this setting when remote controlling the unit via

 

 

the 9 PIN and SERIAL terminal.

LOCAL

NO KEY

Use this to select the buttons on the main unit to be rendered oper-

FUNCTION

EJECT

able when remote controlling the unit via the 9 PIN REMOTE ter-

 

STP + EJT

minal or the SERIAL REMOTE terminal.

 

 ALL KEYS

NO KEY

: No button enabled.

NEXT PAGE

Display the SYSTEM (2/2) menu.

PAGE BACK

Return to the TOP MENU.

SYSTEM (2/2) menu

Items

Setting

 

Contents

DC IN MODE

 OPE OFF

Select the action to perform when power is supplied via the DC IN

 

OPE ON

terminal.

 

 

PLAY

OPE OFF

: Sets the unit to OPERATE OFF

 

 

OPE ON

: Sets the unit to OPERATE ON.

 

 

PLAY

: If a tape has been inserted, the VTR will go into the

 

 

PLAY mode. (AUTO PLAY)

OPERATION

 OFF

Turn ON/OFF the OPERATION LOCK.

LOCK

ON

OFF : Turns off the OPERATION LOCK and enables the buttons

 

 

on the main unit.

 

 

ON : VTR goes into the OPERATE LOCK mode. The buttons and

 

 

the slide switch on the main unit are inhibited. However,

 

 

OPERATE ON and menu operations are still possible.

 

 

Memo

 

 

Even when this setting is OFF, disabling the buttons on the main

 

 

unit while it is controlled via a remote controller connected to the 9

 

 

PIN REMOTE or SERIAL REMOTE terminal is possible, by setting

 

 

the LOCAL FUNCTION item of the REMOTE menu.

PAGE BACK

 

Return to the SYSTEM (1/2).

 

 

EJECT

: Only the EJECT button enabled.

 

 

STP + EJT : Only the STOP button and the EJECT button are ena-

 

 

 

bled.

 

 

ALL KEYS : All operation buttons are enabled.

 

 

Memo

 

 

 

If the OPERATION LOCK item of the SYSTEM (2/2) menu is set

 

 

as ON, the buttons on the main unit will be disabled regardless of

 

 

the setting here.

PREROLL

3SEC

When remote controlling the unit via the 9 PIN REMOTE terminal,

 

5SEC

use this item to set the PREROLL time of the unit. Configurations

 

 7SEC

done via the editing remote controller prevail over other settings.

 

10SE

3SEC

: 3 seconds

 

 

5SEC

: 5 seconds

 

 

7SEC

: 7 seconds

 

 

10SEC

: 10 seconds

 

 

Memo

 

 

 

To enhance editing precision, please set it to at least 7 seconds.

REM FF/REW

 FF/REW

Use this menu item to set the action to be performed when an FF/

MODE

SEARCH

REW command is received via the 9 PIN REMOTE terminal or DV

 

 

terminal.

 

 

 

FF/REW

: Sets the unit to execute FF/REW when a command is

 

 

 

received. This is the usual setting.

 

 

SEARCH : Sets the unit to go into the SEARCH state when a

 

 

 

command is received. Use this setting if the locate(cue

 

 

 

up) function does not work well.

58

59

Image 31
Contents BR-DV3000U Port Cable SupplementImportant In the United Kingdom For Your Safety AustraliaMains Supply AC 230 V ` Table of Contents Daily maintenance and regular inspection PrecautionsCondensation Introduction Precautions on the use of cleaning tapePrecautions on the use of tape Cassette tapeFront panel @ Stop Stop button/LED FF Fast forward button/LED Indicator Audio indicatorREC Record button/LED Play Play button/LEDRear panel Operate button f Still Mode buttonADV button REV buttonMemo On-screen display Contents Method Display at position a Operation in progress Content Display at position B Display for about 3 seconds DUB Inhibit DV Head Cleaning Required OverheatingNo DV Signal DUB Inhibit 48K DUB Inhibit LPModel only Precautions on the use of battery Operable scope of the wireless remote controller Load in 2 batteries Close the coverSwitching on the power PowerTurning off the power Connecting to the AC adapterSelecting the NTSC/PAL signal system Operation Lock modeEjecting the cassette Setting the date and timeEnabling on-screen display Setting/displaying date and timeSetting Recording Connection and settingConnection Recording time codes of a DV input terminal Setting time codesPreset time codes Time code recordingRecording method Recording index signalsRecording Audio dubbing Backup recording function Connection/setting Frame advance reverse playback Basic playback methodSpecial playback function Fast forward/rewindIndex search Special playbackLocate function Variable speed playbackGinning Press the Play button to begin replay Repeat Mode item of the System 1/2 menuRepeat playback Repeat operationPanel to 9 PIN Setting the TC Adjust item of the Time Code menuPlayback signals Applicable modelPanel can be set at any position Remote FF/REW ModeRemote Display the menu for setting Set the unit to the Stop modeDisplay the TOP Menu Contents of the menus Contents of the menus  Remote 2/2 menu Items Setting Display 1/2 menu Model  Display 2/2 menu Alarm  Warning display Displayed regardless of the Display modeTo return to the usual screen  To set the unit to the Stop modeRemote controller Main unit Press the Menu button Power is not supplied even when Diagram of external dimension Unit mm