Kenwood TH-F7E, TH-F6A Single Band Operation, Tone Alert, TIME-OUT Timer, TX Inhibit

Page 45

11 OPERATOR CONVENIENCES

The current programmable frequency range for the band appears.

6Press [] or [MNU].

7Turn the Tuning control or press []/ [] to select the lower limit frequency in MHz.

8Press [] or [MNU] to store the lower limit frequency. To cancel, press [] or [PTT].

The cursor moves to the right and the upper limit frequency blinks.

9Turn the Tuning control or press []/ [] to select the upper limit frequency in MHz.

10Press [] or [MNU] to store the upper limit frequency. To cancel, press [] or [PTT].

Note:

Programmable VFO is available only for A-band.

You cannot program the 100 kHz or lower digits.

The upper limit frequency cannot be selected lower than the selected lower limit frequency.

SINGLE BAND OPERATION

If you do not want to use the A and B-band receivers at the same time, you can turn the A or B-band receiver OFF.

1Press [A/B] to select the band you want to operate.

2Press [F], [A/B].

The frequency of the selected band appears in large font and the other band receiver is turned OFF and muted.

You can also press [A/B] to alternate the A and B-band.

TONE ALERT

Tone Alert provides an audible alarm when signals are received on the frequency you are monitoring. In addition, it shows the number of hours and minutes elapsed after signals have been received. If you use Tone Alert with CTCSS or DCS, it sounds only when a received CTCSS tone or DCS code matches the tone or code you selected.

1Select your desired frequency or memory channel.

2Press [F], [ENT].

• “” icon appears.

When a signal is received, an alarm sounds for 10 seconds and “” icon starts blinking.

Press [PTT] while “” icon is blinking to turn the Tone Alert function OFF.

When 99 hours and 59 minutes pass after a signal has been received, counting stops.

Each time a new signal is received, the elapsed time resets to 00:00.

Note:

While Tone Alert is ON, there is no speaker output when a signal is received. To monitor the signal, press and hold [MONI].

When Tone Alert is ON, APO does not turn the power OFF.

If you switch the transceiver OFF while “” icon is blinking, the transceiver does not back the elapsed time.

When Tone Alert is ON, you can use only the following functions:

[LAMP], [MONI], [SQL], [A/B], [F] then [LAMP], and [F] then [ENT].

3To return to normal dual-band operation, press [F], [A/B] again.

TIME-OUT TIMER

The Time-out Timer limits the time of each transmission. The built-in time-out timer limits each transmission time to a maximum of 10 minutes. Just before the transceiver stops the transmission, a warning beep sounds. It is necessary to protect the transceiver from thermal damage. You cannot turn this function OFF.

Note: A warning beep sounds even if you select Menu No. 19 (KEY BEEP) OFF.

TX INHIBIT

You can inhibit the transmission to prevent unauthorized individuals from transmitting, or to eliminate accidental transmissions while carrying the transceiver.

1Press [MNU].

2Turn the Tuning control or press []/ [] to select Menu No. 8 (TX INHIBIT).

3Press [] or [MNU].

4Turn the Tuning control or press []/ [] to select “ON”.

5Press [] or [MNU] to store the setting. Otherwise, press [] or [PTT] to cancel.

“TX INHIBIT!” appears and an error beep sounds if you press [PTT] while TX Inhibit is activated.

40

Image 45
Contents TH-F6A Precautions Models Covered by this ManualMarket Codes Supplied Accessories FeaturesThank YOU Thank YOUContents Optional Accessories Wireless Remote ControlTroubleshooting SpecificationsInstalling Alkaline Batteries Installing the AntennaInstalling the Belt Clip PreparationConnecting to a Cigarette Lighter Socket Connecting to a Regulated Power SupplyPreparation First QSO Your First QSOKeys and Controls Getting AcquaintedGetting Acquainted Display0VOX 7DCSBasic Operation Selecting a Frequency Getting Acquainted TransmittingENT VFO ENTWhat is a MENU? Menu SetupMenu Access Selecting a Menu LanguageMenu Setup Alphabetical Function List On the Display Menu No Selections DefaultOffset Programming Flow Operating Through RepeatersProgramming Offset Selecting Offset DirectionOperating Through Repeaters Automatic Repeater OffsetActivating Tone Function Selecting a Tone FrequencyReverse Function Tone FREQ. ID ScanAutomatic Simplex Check ASC Parameter Simplex Odd-Split Memory ChannelsCtcss on DCS onUsing the Tuning Control or / Keys Memory Recall ModeUsing a Numeric Keypad Memory Channels Recalling a Memory ChannelNaming a Memory Channel Memory ChannelsDtmf Group Delete Function Memory Channel TransferMemory Group Function Memory \ VFO TransferRecalling the Call Channel Call ChannelReprogramming the Call Channel Channel 0 ~Recalling AN Information Channel Information ChannelsReprogramming the Information Channel WeatherKEY Channel DisplayNormal Scan ScanBand Scan Scan Type PurposeStoring Program Scan Frequency Range Scan Program ScanPerforming the Program Scan Press VFOScan Memory ScanALL-CHANNEL Scan Group ScanCall Scan Using Priority ScanPriority Scan Programming Priority ChannelsUsing Visual Scan VFO Information Channel ScanVisual Scan Scan Using Visual Scan Memory Channel Scan Resume MethodMemory Channel Lockout Selective Call Using CtcssCtcss Selecting a Ctcss FrequencyDCS Using DCSSelective Call Ctcss FREQ. ID Scan Selecting a DCS CodeSelective Call DCS Code ID Scan Manual Dialing Dtmf FunctionsAutomatic Dialer Dtmf TX HoldAdjusting the Pause Duration Adjusting the Dtmf Tone Transmission SpeedDtmf Lock Dtmf FunctionsAbout the B-BAND Utilizing the B-BANDBand Frequency Band Frequency Coverage TH-F6ABAR Antenna Selecting a Mode for the B-BANDUtilizing the B-BAND LSB/ USB/ CW/ AM/ FM/ WFMFine Tuning Activating Fine TuningSelecting a Fine Tuning Frequency Step Battery Remaining Battery LifeBattery Type Operator ConveniencesDisplay Contrast Battery SaverBeat Shift Beep FunctionLamp Tune EnableLock Function Microphone PF Keys OptionalMonitor POWER-ON MessageNarrow Band FM Operation Programmable VFOSingle Band Operation TIME-OUT TimerTone Alert TX InhibitVolume Balance TX PowerVOX VOICE-OPERATED Transmit VOX GainVOX on Busy VOX Delay TimePreparation Wireless Remote Control TH-F6A onlyControl Operation Tone SELOptional Accessories EMC-3 HMC-3PG-2W PG-3J SP/MIC Jack Interfacing to PeripheralsSelecting SP/MIC Jack Function SP/MICInterfacing to Peripherals Troubleshooting Backup BatteryGeneral Information Troubleshooting TroubleshootingProblem Probable Cause Corrective Action Press A/B+Troubleshooting Microprocessor Reset Operation Notices Internal Beats Frequency Formula TH-F6A TH-F7E SpecificationsLSB/ USB/ CW/ AM/ FM SpecificationsTV Channels VHF AppendixAppendix TV Channels UHFCitizen Band Channels Marine Channels VHFCtcss IndexDCS Dtmf