Haier HSU-12HS03/R2DB, HSU-09HS03/R2DB service manual Trouble Records

Page 33

Domestic Air Conditioner

HSU-12HS03/R2(DB)

Model: HSU-09HS03/R2(DB)

receives wrong EEPROM signals from the outdoor unit.

. In this case the control and emergency operation are not allowed.

. Power-off to disarm.

14 .Trouble Records

. There are no lists if there are no error code records.

. The malfunction display will automatically disappear after 10 seconds.

The remote control accepts stop signal only. The malfunction record may end according to the ON/OFF or remote-control’s stop signal

. Models with EEPROM can store the records when they are replugged to the power.

15. Special functions

1The indoor unit operates only

a. To enter into this function please press the sleep key 6 times with 6 beeps in 7 seconds under the none-power-failure-compensation mode.

b. The indoor unit operates as follows after entering into the function.

The indoor unit operates and communicates according to the setting without processing the signals from the outdoor unit but needs to send signals to the outdoor unit without stop.

c. To exit this function pleasepress the OFF key of the remote-controller or the emergency key to power off the unit. You can also unplug the machine to exit this function.

When the indoor unit operates independently, it imitates the outdoor unit to send the following signals to the indoor unit.

Output frequency 58 Hz ,error frost removing state: 17654=0001,13=0,121=01 ,external temperature level K54=00, the indoor heat-exchange temperature is fixed at 47

33

Image 33
Contents Domestic Air Conditioner Models Content Description Product Model Coding Series Introduction Introductory Remarks Standard Situation/Conditions Specifications Specification 2700950-3400W Curves of performance of compressor Curent a Input W Input Power Domestic Air Conditioner Outdoor unit NE T Dime Nsions for Indoor Unit Knock-down drawings Domestic Air Conditioner Domestic Air Conditioner Model HSU-12HS03/R2DB KNOCK-DOWN Drawings for Outdoor UNITHSU-09/12HS03/R2DB No. Spare parts Spare parts description in english Model QTY Brief introduction to electrical Control functions Indoor Unit Part Tchahl Tchacl Silent Fqshot Heating Moisture Fqdry Removing Cooling SLO Frequency control form for wind volume THHOT1 Refer to the temperature level control function Domestic Air Conditioner THLHEATBL3 THLHEATBL2 THLHEATBL1 THLHEATBL0 THHEAT6 THHEAT5 THHEAT4 THHEAT3 THHEAT2 THHEAT1 THHEAT0 Trouble Records Outdoor Unit Part . Conditions to enter into the defrosting stage Domestic Air Conditioner Domestic Air Conditioner Wiring diagram Indoor Unit Diagram Wiring Diagram of Outdoor Unit Circuit Diagram Indoor Unit Outdoor Unit Abnormity Diagnose Or Unit Part Overheat .The system is lack Eeprom LED Trouble Shooting Domestic Air Conditioner Refrigerating Cycle Diagram Refrigerating cycle diagram Noise level test chart and air velocity distribution Noise level test chart Air velocity distribution Installation manual Installation Manual of Room Air Conditioner Power Source Making a Hole on the Wall and Fitting the Piping Hole Cover Installation of the Indoor Unit Drawing of pipe Indoor unit Outdoor unit Outdoor Unit Outdoor Unit On Drainage Sincere Forever