Haier HSU-09HS03/R2DB, HSU-12HS03/R2DB No. Spare parts Spare parts description in english Model

Page 20

 

 

 

 

 

 

 

Domestic Air Conditioner

Model: HSU-09HS03/R2(DB)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Edition:2004/10/26

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No. in

Spare parts

Spare parts description in english

Model

 

QTY

Failure

 

The proportion

remark

 

 

 

explode

number

 

 

 

 

.

 

rate

 

of the spare part

 

 

 

 

d view

 

 

 

 

 

 

 

 

 

 

 

stock

 

 

 

 

1

 

001A0100017

Front grille

 

HSU-09HS03/R2(DB)

 

 

1

 

 

 

 

 

 

 

2

 

001A1101009

Front panel

 

HSU-09HS03/R2(DB)

 

 

1

 

 

 

 

 

 

 

3

 

0010203662

Fan

 

HSU-09HS03/R2(DB)

 

 

1

 

 

 

*

 

 

 

4

 

0010403487

Motor

 

HSU-09HS03/R2(DB)

 

 

1

 

 

 

*

 

 

 

5

 

0010100419

Frame for motor

 

HSU-09HS03/R2(DB)

 

 

1

 

 

 

 

 

 

 

6

 

0010706498

Heat exchanger

 

HSU-09HS03/R2(DB)

 

 

1

 

 

 

 

 

 

 

7

 

001A5736055

Fixed clip forenviroment

temp.

HSU-09HS03/R2(DB)

 

 

1

 

 

 

 

 

 

 

 

sensor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

 

001A3800082

Temperature sensor

 

HSU-09HS03/R2(DB)

 

 

1

 

 

 

*

 

 

 

9

 

0010101388

Back panel

 

HSU-09HS03/R2(DB)

 

 

1

 

 

 

 

 

 

 

10

 

001A1101010

Top panel

 

HSU-09HS03/R2(DB)

 

 

1

 

 

 

 

 

 

 

11

 

001A3900056

Compressor temperature sensor

HSU-09HS03/R2(DB)

 

 

1

 

 

 

*

 

 

 

12

 

001A3900055

Tube temperature sensor

 

HSU-09HS03/R2(DB)

 

 

1

 

 

 

*

 

 

 

13

 

0010706509

Entering gas pipe

 

HSU-09HS03/R2(DB)

 

 

1

 

 

 

 

 

 

 

14

 

0010706497

Capillary Tube

 

HSU-09HS03/R2(DB)

 

 

1

 

 

 

 

 

 

 

15

 

0010403022

4-way valve coil

 

HSU-09HS03/R2(DB)

 

 

1

 

 

 

*

 

 

 

16

 

0010704488

4-way valve

 

HSU-09HS03/R2(DB)

 

 

1

 

 

 

 

 

 

 

17

 

0010705988

Stop valve

 

HSU-09HS03/R2(DB)

 

 

1

 

 

 

 

 

 

 

18

 

0010705255

Stop valve

 

HSU-09HS03/R2(DB)

 

 

1

 

 

 

 

 

 

 

19

 

001A5102050

Flange Nut

 

HSU-09HS03/R2(DB)

 

 

3

 

 

 

 

 

 

 

20

 

0010706492

Compressor

 

HSU-09HS03/R2(DB)

 

 

1

 

 

 

*

 

 

 

21

 

001A17621544

Cushion

 

HSU-09HS03/R2(DB)

 

 

1

 

 

 

 

 

 

 

22

 

001A1101014

Bottom plate

 

HSU-09HS03/R2(DB)

 

 

1

 

 

 

 

 

 

 

23

 

001A1436042

Service cover

 

HSU-09HS03/R2(DB)

 

 

1

 

 

 

 

 

 

 

24

 

0010804196

Separating plate

 

HSU-09HS03/R2(DB)

 

 

1

 

 

 

 

 

 

 

25

 

001A0100427

Reactor box

 

HSU-09HS03/R2(DB)

 

 

1

 

 

 

 

 

 

 

26

 

0010403365

Reactor

 

HSU-09HS03/R2(DB)

 

 

1

 

 

 

*

 

 

 

27

 

0010403368

Power Module

 

HSU-09HS03/R2(DB)

 

 

1

 

 

 

*

 

 

 

28

 

0010403521

PCB

 

HSU-09HS03/R2(DB)

 

 

1

 

 

 

*

 

 

 

29

 

0010403520

Capacitor board

 

HSU-09HS03/R2(DB)

 

 

1

 

 

 

*

 

 

 

30

 

001A4000105

Terminal Block

 

HSU-09HS03/R2(DB)

 

 

1

 

 

 

 

 

 

 

1,The failer rate and the proportion of the spare-part stock are regarded as the reference of the stock for spare-parts;The first

 

 

 

time should be stocked accroded with the proportion of the spare-parts,and it should be adjusted with the actual quantity 3

 

 

 

months later.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2,easy-damaged;The spare-part which is often damaged and the customer must stock in the spare-parts warehouse,and

 

 

 

should be marked with"*"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3,possible damaged:The spare-part which is not often damaged like the easy damaged one and the customer may stock in

 

 

 

the spare-part warehouse accord with the actual case,should be marked with " ".

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4,not need provided :The spare-part which is seldom

damaged or the maintenance man could not maitmains.The spare

 

 

 

parts may be air freighted by the factory if they were damaged.The customer nees not

stock in the spare-part

 

 

 

warehouse,should be marked with " x ".

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5,Above should be improved accord with the reply of the market half a year per time.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6.The spare parts price on net is FOB Qingdao term.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20

Image 20
Contents Domestic Air Conditioner Models Content Description Product Model Coding Series Introduction Introductory Remarks Standard Situation/Conditions Specifications Specification 2700950-3400W Curves of performance of compressor Curent a Input W Input Power Domestic Air Conditioner Outdoor unit NE T Dime Nsions for Indoor Unit Knock-down drawings Domestic Air Conditioner Domestic Air Conditioner Model HSU-12HS03/R2DB KNOCK-DOWN Drawings for Outdoor UNITHSU-09/12HS03/R2DB No. Spare parts Spare parts description in english Model QTY Brief introduction to electrical Control functions Indoor Unit Part Tchahl Tchacl Silent Fqshot Heating Moisture Fqdry Removing Cooling SLO Frequency control form for wind volume THHOT1 Refer to the temperature level control function Domestic Air Conditioner THLHEATBL3 THLHEATBL2 THLHEATBL1 THLHEATBL0 THHEAT6 THHEAT5 THHEAT4 THHEAT3 THHEAT2 THHEAT1 THHEAT0 Trouble Records Outdoor Unit Part . Conditions to enter into the defrosting stage Domestic Air Conditioner Domestic Air Conditioner Wiring diagram Indoor Unit Diagram Wiring Diagram of Outdoor Unit Circuit Diagram Indoor Unit Outdoor Unit Abnormity Diagnose Or Unit Part Overheat .The system is lack Eeprom LED Trouble Shooting Domestic Air Conditioner Refrigerating Cycle Diagram Refrigerating cycle diagram Noise level test chart and air velocity distribution Noise level test chart Air velocity distribution Installation manual Installation Manual of Room Air Conditioner Power Source Making a Hole on the Wall and Fitting the Piping Hole Cover Installation of the Indoor Unit Drawing of pipe Indoor unit Outdoor unit Outdoor Unit Outdoor Unit On Drainage Sincere Forever