Haier HSU-12HS03/R2DB, HSU-09HS03/R2DB service manual Indoor Unit Part

Page 23

Domestic Air Conditioner

HSU-12HS03/R2(DB)

Model: HSU-09HS03/R2(DB)

INDOOR UNIT PART

1. Application Range

This function guide can be used for the HSU-09HS03/R2(DB) air-conditioners and other frequency-convertings made by Headquarters of Qingdao Haier Air-conditioner Co.,Ltd

Indexes in this guide (symblised by parameters) refer to the indexes stored in the EEPROM. Please refer to the EEPROM index chart.

2. Temperature Ajusting function

. This function will decide the outdoor-set’s running speed according to the domestic temperature and the set temperature.

. Control the domestic blower fan according to the need for temperature adjusting when the wind rate is automatic

. Control the domestic blower fan according to the disc-tube temperature when it’s running for heating.

2.1.1 Indoor environment temperature sensor specification

Under the conditions of short circuit or open circuit, the indicative light will flash an alarm and the indoor blower fan stops. When it returns to normal condtions, the operation will come back to normal.

Short circuit

Temperature: over 126. Sixteen scales: over F8H. Resistance value: below 0.65 K.

Voltage: over 4.85 V Normal temperature

Temperature: 25 . Sixteen scale: 40H Resistance value: 23K . Voltage: 2.33 V Disconnection

Temperature : below minus 31 . Sixteen scale: below 08H . Resistance value:

below 620K. Voltage: below 0.15 V

.B index=4200 R(25)=23K

2.1.2During the time when the heat running starts and indoor blower fan stops or when the warm boot starts and within 30 seconds after the indoor blower fan starts, the resistance value for indoor environment temperature sensor will be neglected. 2.2 The frequency kept when the frequency rises.

. When the operation enters into the work mode, in order to insure the full oil-returning, some frequency should be kept for some time.

 

Indication time

 

Indication

 

 

 

frequency

Cooling & moisture

Heating

Heating

Frequency kept

removing

 

& Frost removing

 

60 seconds

60 seconds

30 seconds

58 Hz

 

 

 

 

When the unit is switched on and the forcible running is over, the temperature level control starts.

2.3 Modify the set temperature

The set temperature can be modified according to the unit’s operation mode, wind volume or whether it is under forceful running condition.

The modification of wind volume is only limited within the switch between weak

23

Image 23
Contents Domestic Air Conditioner Models Content Description Product Model Coding Series Introduction Introductory Remarks Standard Situation/Conditions Specifications Specification 2700950-3400W Curves of performance of compressor Curent a Input W Input Power Domestic Air Conditioner Outdoor unit NE T Dime Nsions for Indoor Unit Knock-down drawings Domestic Air Conditioner Domestic Air Conditioner Model HSU-12HS03/R2DB KNOCK-DOWN Drawings for Outdoor UNITHSU-09/12HS03/R2DB No. Spare parts Spare parts description in english Model QTY Brief introduction to electrical Control functions Indoor Unit Part Tchahl Tchacl Silent Fqshot Heating Moisture Fqdry Removing Cooling SLO Frequency control form for wind volume THHOT1 Refer to the temperature level control function Domestic Air Conditioner THLHEATBL3 THLHEATBL2 THLHEATBL1 THLHEATBL0 THHEAT6 THHEAT5 THHEAT4 THHEAT3 THHEAT2 THHEAT1 THHEAT0 Trouble Records Outdoor Unit Part . Conditions to enter into the defrosting stage Domestic Air Conditioner Domestic Air Conditioner Wiring diagram Indoor Unit Diagram Wiring Diagram of Outdoor Unit Circuit Diagram Indoor Unit Outdoor Unit Abnormity Diagnose Or Unit Part Overheat .The system is lack Eeprom LED Trouble Shooting Domestic Air Conditioner Refrigerating Cycle Diagram Refrigerating cycle diagram Noise level test chart and air velocity distribution Noise level test chart Air velocity distribution Installation manual Installation Manual of Room Air Conditioner Power Source Making a Hole on the Wall and Fitting the Piping Hole Cover Installation of the Indoor Unit Drawing of pipe Indoor unit Outdoor unit Outdoor Unit Outdoor Unit On Drainage Sincere Forever