Haier HSU-12HS03/R2DB, HSU-09HS03/R2DB service manual Installation Manual of Room Air Conditioner

Page 57

Domestic Air Conditioner

HSU-12HS03/R2(DB)

Model: HSU-09HS03/R2(DB)

Installation Manual of Room Air Conditioner

Read this manual before installation.

Explain sufficiently the operating means to the user according to this manual.

Necessary Tools for Installation

1.Driver

5.Torque wrench (17mm,22mm,26mm)

9.Nipper

12.Reamer

2.Hacksaw

6.Pipe cutter

10.Gas leakage detector or

 

3.Hole core drill

7.Flaring tool

soap-and-water solution

 

4.Spanner(17,19 and 26mm)

8.Knife

11.Measuring tape

 

Accessory parts

Accessory parts

Remote controller

R-03 dry battery

Drawing for the installation of indoor and outdoor units

The modes adopt HFC free refrigerant R410A

Mounting plate

Drain hose

Steel nail,cement

Screw

Plastic cap

 

Drain-elbow

Cover

Cushion

Connecting cable

Pipe supporting plate

Optional parts for piping

Mark

Parts name

Non-adhesive tape

Adhesive tape

Saddle(L.S) with screws

Connecting electric cable for indoor and outdoor

Drain hose

Heat insulating material

Piping hole cover

Arrangement of piping directions

 

Rear left

Left

Rear

right

 

 

Right

 

Below

more

than

 

 

10cm

 

 

more than 10cm

Attention must be paid to the rising up of drain hose

10cm than more

60cm

 

than

 

more

more

 

than

 

15cm

The marks from to in the figure are the parts' numbers

The distance between the indoor unit and the floor should be more than 2mm

No.

57

Image 57
Contents Domestic Air Conditioner Models Content Description Product Model Coding Series Introduction Introductory Remarks Standard Situation/Conditions Specifications Specification 2700950-3400W Curves of performance of compressor Curent a Input W Input Power Domestic Air Conditioner Outdoor unit NE T Dime Nsions for Indoor Unit Knock-down drawings Domestic Air Conditioner Domestic Air Conditioner Model HSU-12HS03/R2DB KNOCK-DOWN Drawings for Outdoor UNITHSU-09/12HS03/R2DB No. Spare parts Spare parts description in english Model QTY Brief introduction to electrical Control functions Indoor Unit Part Tchahl Tchacl Silent Fqshot Heating Moisture Fqdry Removing Cooling SLO Frequency control form for wind volume THHOT1 Refer to the temperature level control function Domestic Air Conditioner THLHEATBL3 THLHEATBL2 THLHEATBL1 THLHEATBL0 THHEAT6 THHEAT5 THHEAT4 THHEAT3 THHEAT2 THHEAT1 THHEAT0 Trouble Records Outdoor Unit Part . Conditions to enter into the defrosting stage Domestic Air Conditioner Domestic Air Conditioner Wiring diagram Indoor Unit Diagram Wiring Diagram of Outdoor Unit Circuit Diagram Indoor Unit Outdoor Unit Abnormity Diagnose Or Unit Part Overheat .The system is lack Eeprom LED Trouble Shooting Domestic Air Conditioner Refrigerating Cycle Diagram Refrigerating cycle diagram Noise level test chart and air velocity distribution Noise level test chart Air velocity distribution Installation manual Installation Manual of Room Air Conditioner Power Source Making a Hole on the Wall and Fitting the Piping Hole Cover Installation of the Indoor Unit Drawing of pipe Indoor unit Outdoor unit Outdoor Unit Outdoor Unit On Drainage Sincere Forever