Graco 312877C Fluid Inlet and Outlet Ports, Aluminum 1050A, Stainless Steel 1050S

Page 12

Installation

Fluid Inlet and Outlet Ports

NOTE: Remove and reverse the manifold(s) to change the orientation of inlet or outlet port(s). Follow Torque Instructions on page 16.

Aluminum (1050A)

The fluid inlet and outlet manifolds each have four 1 in. npt(f) or bspt threaded ports (FIG. 3, M, N). Close off the unused ports, using the supplied plugs.

Plastic (1050P, 1050C)

The fluid inlet and outlet manifolds each have a 1 in. raised face ANSI/DIN flange (FIG. 4, M, N) in either a center or end location. Connect 1 in. standard flanged plastic pipe to the pump.

See FIG. 5.

Graco standard pipe flange kits are available in polypropylene (239005), stainless steel (239008), and PVDF (239009). These kits include:

the pipe flange

a PTFE gasket

four 1/2 in. bolts, spring lock washers, flat washers and nuts.

Be sure to lubricate the threads of the bolts and torque to 10-15 ft-lb (14-20 N•m). Follow the bolt tightening sequence and do not over-torque.

Stainless Steel (1050S)

The fluid inlet and outlet manifolds each have one 1 in. npt (f) or bspt threaded port.

V

U

N

T

S

U W

M

ti14181a

Bolt tightening sequence

3 1

2 4

X 1

ti14182a

Key:

M1 in. fluid inlet flange

N1 in. fluid outlet flange

S1 in. standard pipe flange

TPTFE gasket

UFlat washer

VNut

WLock washer

XBolt

1Torque to 10-15 ft-lb (14-20 N•m). Do not over-torque.

FIG. 5. Flange connections (plastic pumps only, 1050P and 1050C models)

12

312877C

Image 12
Contents Important Safety Instructions 1050P Polypropylene 1050C Conductive1050A Aluminum 1050S Stainless SteelContents Related ManualsPump Matrix Atex CertificationsFire and Explosion Hazard Plastic Parts Cleaning Solvent Hazard Installation Tighten Fasteners Before SetupMounting GroundingFluid supply container Follow local code Reed Switch Air LineAir Exhaust Ventilation Fluid Supply Line Fluid Outlet LineKey Typical bung-mount installation aluminum, 1050A, pump shown C BA Fluid Inlet and Outlet Ports Aluminum 1050AStainless Steel 1050S Bolt tightening sequenceFluid Pressure Relief Valve Fluid pressure relief kit Aluminum pumps only, 1050A modelsPressure Relief Procedure Starting and Adjusting the Pump OperationFlush the Pump Before First Use Maintenance Torque Instructions Torque sequence312877C Dimensions and Mounting Aluminum 1050APolypropylene 1050P and Conductive Polypropylene 1050C Nptf air inletIn. ANSI/DIN flange Stainless Steel 1050S Performance Charts Fluid PressureAir Consumption Technical Data Fluid Temperature Range Fluid Temperature RangeAluminum or Stainless Steel PumpsGraco Standard Husky Pump Warranty Graco Information