Graco 312877C important safety instructions Torque Instructions, Torque sequence

Page 16

Maintenance

Torque Instructions

NOTE: Fluid cover and manifold fasteners have a thread-locking adhesive patch applied to the threads. If this patch is excessively worn, the fasteners may loosen during operation. Replace screws with new ones or apply medium-strength (blue) Loctite or equivalent to the threads.

If fluid cover or manifold fasteners have been loosened, it is important to torque them using the following procedure to improve sealing.

NOTE: Always completely torque fluid covers before torquing manifolds.

Start all fluid cover screws a few turns. Then turn down each screw just until head contacts cover. Then turn each screw by 1/2 turn or less working in a crisscross pattern to specified torque. Repeat for manifolds.

Fluid cover and manifold fasteners: 100 in-lb (11.3 N•m)

Retorque the air valve fasteners (V) in a criss- cross pattern to specified torque.

Plastic center sections: 55 in-lb (6.2 N•m)

Metal center sections: 80 in-lb (9.0 N•m)

1

8

6

4

13 9

15 11

V FIG. 7. Torque sequence

3

5

7

2

ti13845a

12 16

1014

ti13846a

16

312877C

Image 16
Contents Important Safety Instructions 1050P Polypropylene 1050C Conductive1050A Aluminum 1050S Stainless SteelContents Related ManualsPump Matrix Atex CertificationsFire and Explosion Hazard Plastic Parts Cleaning Solvent Hazard Installation Tighten Fasteners Before SetupGrounding MountingFluid supply container Follow local code Air Line Reed SwitchAir Exhaust Ventilation Fluid Outlet Line Fluid Supply LineKey Typical bung-mount installation aluminum, 1050A, pump shown C BA Fluid Inlet and Outlet Ports Aluminum 1050AStainless Steel 1050S Bolt tightening sequenceFluid Pressure Relief Valve Fluid pressure relief kit Aluminum pumps only, 1050A modelsOperation Pressure Relief Procedure Starting and Adjusting the PumpFlush the Pump Before First Use Maintenance Torque Instructions Torque sequence312877C Dimensions and Mounting Aluminum 1050ANptf air inlet Polypropylene 1050P and Conductive Polypropylene 1050CIn. ANSI/DIN flange Stainless Steel 1050S Fluid Pressure Performance ChartsAir Consumption Technical Data Fluid Temperature Range Fluid Temperature RangeAluminum or Stainless Steel PumpsGraco Standard Husky Pump Warranty Graco Information