Graco 312877C important safety instructions Performance Charts, Fluid Pressure, Air Consumption

Page 21

Performance Charts

Test Conditions: Pump tested in water with inlet submerged.

 

 

120

 

 

A

 

bar)

(0.83. 8.3)

 

 

 

 

 

 

 

100

 

 

 

 

(MPa,

 

 

 

 

(0.7, 7.0)

 

 

B

 

 

 

 

 

 

80

 

 

 

psi-

 

 

 

 

(0.55, 5.5)

 

 

 

 

 

 

 

 

Operating Air Pressure

Pressure

40

 

 

 

125 psi (0.83 MPa, 8.3 bar)

 

 

 

 

 

60

 

 

C

A

 

(0.41, 4.1)

 

 

 

 

 

 

 

 

100 psi (0.7 MPa, 7.0 bar)

Fluid

(0.28, 2.8)

 

 

D

20

 

 

 

B

 

 

 

 

 

C

 

(0.14, 1.4)

 

 

 

70 psi (0.48 MPa, 4.8 bar)

 

0

 

 

 

 

 

 

 

 

Performance Charts

Fluid Pressure

D

40 psi (0.28 MPa, 2.8 bar)

How to Read the Charts

0

5

10

15

20

25

30

35

40

45

50

(19)(38) (57) (76) (95) (114) (133) (152) (170) (189)

Fluid Flow — gpm (lpm)

1.Locate fluid flow rate along bottom of chart.

2.Follow vertical line up to intersection with selected operating air pressure curve.

3.Follow left to scale to read fluid outlet pressure (top chart) or

air consumption (bottom chart).

Air Consumption - scfm (cubic meters/min.)

80

(2.24)

60

(1.68)

40

(1.12)

20

(0.56)

0

0

Air Consumption

A

 

B

 

C

 

D

5

10

15

20

25

30

35

40

45

50

(19)(38) (57) (76) (95) (114) (133) (152) (170) (189)

Fluid Flow — gpm (lpm)

312877C

21

Image 21
Contents 1050P Polypropylene 1050C Conductive Important Safety Instructions1050A Aluminum 1050S Stainless SteelRelated Manuals ContentsAtex Certifications Pump MatrixFire and Explosion Hazard Plastic Parts Cleaning Solvent Hazard Tighten Fasteners Before Setup InstallationMounting GroundingFluid supply container Follow local code Reed Switch Air LineAir Exhaust Ventilation Fluid Supply Line Fluid Outlet LineKey Typical bung-mount installation aluminum, 1050A, pump shown C BA Aluminum 1050A Fluid Inlet and Outlet PortsStainless Steel 1050S Bolt tightening sequenceFluid pressure relief kit Aluminum pumps only, 1050A models Fluid Pressure Relief ValvePressure Relief Procedure Starting and Adjusting the Pump OperationFlush the Pump Before First Use Maintenance Torque sequence Torque Instructions312877C Aluminum 1050A Dimensions and MountingPolypropylene 1050P and Conductive Polypropylene 1050C Nptf air inletIn. ANSI/DIN flange Stainless Steel 1050S Performance Charts Fluid PressureAir Consumption Technical Data Fluid Temperature Range Fluid Temperature RangeAluminum or Stainless Steel PumpsGraco Information Graco Standard Husky Pump Warranty